EUVIMEDOpdag EUVIMED
Crossref

A field map updating algorithm to improve fat‐water spiral imaging

Tzu Cheng Chao iD, Dinghui Wang iD, Guruprasad Krishnamoorthy iD, James G Pipe iD

Magnetic Resonance in Medicine · 2023

DOI: 10.1002/mrm.29697 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2023. Written by Tzu Cheng Chao and 3 co-authors. Institution: Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA. Major MEDLINE topics: Water, Magnetic Resonance Imaging. Cited 2 times so far (Crossref); 19 references. Funded by: Philips.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

An accurate field map is essential to separate fat and water signals in a dual‐echo chemical shift encoded spiral MRI scan. A rapid low‐resolution B 0 map prescan is usually performed before each exam. Occasional inaccuracy in these field map estimates can lead to misclassification of the water and fat signals as well as blurring artifacts in the reconstruction. The present work proposes a self‐consistent model to evaluate residual field offsets according to the image data to improve the reconstruction quality and facilitate the scan efficiency. Theory and Methods The proposed method compares the phase differences of the two‐echo data after correcting for fat frequency offsets. A more accurate field map is approximated according to the phase discrepancies and improved image quality. Experiments were conducted with simulated off‐resonance on a numerical phantom, five volunteer head scans, and four volunteer abdominal scans for validation.

Results

The initial reconstruction of the demonstrated examples exhibit blurring artifacts and misregistration of fat and water because of the inaccuracy of the field map. The proposed method updates the field map to amend the fat and water estimation and improve image quality.

Conclusions

This work presents a model to improve the quality of fat‐water imaging of the spiral MRI by estimating a better field map from the acquired data. It allows reducing the field map pre‐scans before each spiral scan under normal circumstances to increase scan efficiency.

Subjects

MeSH terms (MEDLINE)

WaterMagnetic Resonance ImagingHumansAlgorithmsPhantoms, ImagingBody WaterImage Processing, Computer-AssistedArtifacts

Author keywords

fat-water separationfield mapspiral imaging

Substances

Water

Authors and institutions

  • Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
  • MR R and D, Royal Philips, Rochester, Minnesota, USA.

ORCID profiles: Tzu Cheng Chao, Dinghui Wang, Guruprasad Krishnamoorthy, James G Pipe

Funding

  • Philips

Cite

APA

Chao, T. C., Wang, D., Krishnamoorthy, G., & Pipe, J. G. (2023). A field map updating algorithm to improve fat‐water spiral imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29697

Vancouver

Chao TC, Wang D, Krishnamoorthy G, Pipe JG. A field map updating algorithm to improve fat‐water spiral imaging. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29697

BibTeX
@article{Chao2023,
  author = {Chao, Tzu Cheng and Wang, Dinghui and Krishnamoorthy, Guruprasad and Pipe, James G},
  title = {A field map updating algorithm to improve fat‐water spiral imaging},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  doi = {10.1002/mrm.29697}
}
Start for free →