Chemical Shift Separated and Compensated Ultra‐Short Echo‐Time Imaging
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70327 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Martin Krämer und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Diagnostic and Interventional Radiology, Jena University Hospital, Friedrich Schiller University Jena, Jena, Germany. Hauptthemen laut MEDLINE: Image Enhancement, Adipose Tissue, Image Interpretation, Computer-Assisted, Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Purpose
To develop a modified binomial excitation scheme for ultra‐short echo‐time (UTE) imaging that allows for the separation of water and fat signals and the correction of chemical shift artifacts.
Methods
Theoretical derivation and numerical Bloch simulations were performed for a modified water‐excitation binomial pulse scheme to calculate fat and water signals as well as a chemical shift corrected UTE image from two acquisitions with these configurations. Chemical shift correction was applied at the readout level by multiplying the fat signal with a corresponding linear phase term. Measurements with the proposed binomial pulse scheme were performed at 3 T and 7 T.
Results
Imaging results at 7 T and 3 T showed robust fat and water separation and images free of chemical shift‐induced blurring after applying the proposed method. Compared to standard UTE, the corrected UTE images exhibited improved tissue boundary delineation and improved visibility of fine details. Bloch simulations demonstrated that deviations of the phase differences between water and fat from the analytical solution were below 1% for typical UTE acquisition parameters.
Conclusion
The proposed binomial excitation scheme and post‐processing effectively separate water and fat signals and correct for chemical shift artifacts in UTE imaging, providing improved image quality, especially at high field strengths.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Diagnostic and Interventional Radiology, Jena University Hospital, Friedrich Schiller University Jena, Jena, Germany.
- Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital, Friedrich Schiller University Jena, Jena, Germany.
- Siemens Healthcare Limited, Burnaby, British Columbia, Canada.
- Swiss Center for Musculoskeletal Imaging (SCMI), Balgrist Campus, Zurich, Switzerland.
- Swiss Innovation Hub, Siemens Healthineers International AG, Zurich, Switzerland.
ORCID-Profile: Martin Krämer, Jürgen R Reichenbach, Stefan Sommer
Förderung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Krämer, M., Cui, L., Reichenbach, J. R., & Sommer, S. (2026). Chemical Shift Separated and Compensated Ultra‐Short Echo‐Time Imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70327
Vancouver
Krämer M, Cui L, Reichenbach JR, Sommer S. Chemical Shift Separated and Compensated Ultra‐Short Echo‐Time Imaging. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70327
BibTeX
@article{Krmer2026,
author = {Krämer, Martin and Cui, Lumeng and Reichenbach, Jürgen R and Sommer, Stefan},
title = {Chemical Shift Separated and Compensated Ultra‐Short Echo‐Time Imaging},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70327}
}
EUVIMED