Myelin water imaging from accelerated 3D-GRASE acquisitions using subspace constrained reconstruction
Magnetic Resonance Materials in Physics, Biology and Medicine · 2025
DOI: 10.1007/s10334-025-01276-w ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, 2025. Verfasst von Riwaj Byanju und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Myelin Sheath, Magnetic Resonance Imaging, Water. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: H2020 Marie Skłodowska-Curie Actions.
Abstract (Originalsprache)
Purpose
Quantitative MRI markers, such as myelin water fraction (MWF) and geometric mean $$T_2$$ T 2 (IET2) (the intra-/extra-cellular water compartment), can be biomarkers for various brain disorders. However, these markers require acquiring multi-echo spin-echo images which requires long scan times. Undersampled 3D-GRAdient Echo and Spin Echo (3D-GRASE) scans with parallel imaging have been used for faster scans. Still, further acceleration is desirable. Reconstruction techniques that utilize redundancy along the echoes could be employed to achieve artifact-free maps at higher acceleration. This work examines the possibility of using one such technique, subspace constrained reconstruction (SCR), for further accelerating the 3D-GRASE scan.
Methods
We propose two techniques to undersample the 3D-GRASE acquisition and exploit the redundancy across echoes. We retrospectively undersample fully sampled data from phantom and in-vivo acquisition to test these techniques. We compared our results for mapping MWF and IET2 to a reference multi-spin-echo technique. Additionally, we compare the proposed, state-of-the-art, and reference techniques with prospectively undersampled in-vivo acquisitions.
Results
The RMSD of the MWF in retrospectively undersampled data was worse for the proposed techniques than the state-of-the-art. However, for IET2, RMSD was similar or slightly improved. In prospectively undersampled scans, undersampling artifacts deteriorated MWF maps, but not IET2 maps, which were within 10 ms of the reference map.
Conclusion
Our findings suggest that exploiting redundancy across echoes does not result in additional acceleration beyond the current state-of-the-art for MWF mapping, while it is possible to accelerate beyond state-of-the-art for IET2 mapping.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands.
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands. d.poot@erasmusmc.nl.
Förderung
- H2020 Marie Skłodowska-Curie Actions
Zitieren
APA
Byanju, R., Klein, S., Cristobal-Huerta, A., Hernandez-Tamames, J. A., & Poot, D. H. J. (2025). Myelin water imaging from accelerated 3D-GRASE acquisitions using subspace constrained reconstruction. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-025-01276-w
Vancouver
Byanju R, Klein S, Cristobal-Huerta A, Hernandez-Tamames JA, Poot DHJ. Myelin water imaging from accelerated 3D-GRASE acquisitions using subspace constrained reconstruction. Magnetic Resonance Materials in Physics, Biology and Medicine. 2025. doi:10.1007/s10334-025-01276-w
BibTeX
@article{Byanju2025,
author = {Byanju, Riwaj and Klein, Stefan and Cristobal-Huerta, Alexandra and Hernandez-Tamames, Juan A and Poot, Dirk H J},
title = {Myelin water imaging from accelerated 3D-GRASE acquisitions using subspace constrained reconstruction},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2025},
doi = {10.1007/s10334-025-01276-w}
}
EUVIMED