Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Renée-Claude Bider und 5 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics Unit, McGill University, Montréal, Québec, Canada. Hauptthemen laut MEDLINE: Adipose Tissue, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada (NSERC), Fonds de Recherche du Québec - Santé, Research Institute of the McGill University Health Centre.
Abstract (Originalsprache)
Purpose
To improve on a multiparametric technique—known as Fat DESPOT—to map the fat‐ and water‐specific (, ), , and proton density fat fraction (PDFF) by upgrading the parameter initialization and introducing explicit model sensitivity to the complex phase of the water and fat signals.
Methods
We compared three‐point Dixon and Graph Cut (GC) approaches to initial guesses for Fat DESPOT in experiments at 3 T in fat emulsion phantoms. Also in the phantom, we compared magnitude‐based Fat DESPOT (Fat DESPOT m ) to a magnitude approach modeling the phases of fat and water separately (Fat DESPOT mϕ ), and two models for complex data (Fat DESPOT c , Fat DESPOT cϕ ). The complex approaches, which performed best, were used in the lower leg and abdomen of healthy human participants.
Results
In phantoms, Fat DESPOT using three‐point Dixon and GC returned similar parameter estimates and precision, though the former deviated from the overall trend at 50% nominal fat fraction. The complex models showed the best agreement with reference PDFF (average error 1.2% ± 1.2%) and the lowest combined standard deviation across ROIs, for PDFF, , and (maximum = 0.13%, 0.19 s −1 , and 0.009 s −1 , respectively).
Conclusion
With more precise and , more accurate PDFF, and more versatile echo time selection, this work demonstrates the advantages of Fat DESPOT multiparametric mapping with complex fitting and GC‐based parameter initialization.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Medical Physics Unit, McGill University, Montréal, Québec, Canada.
- Department of Physics, McGill University, Montréal, Québec, Canada.
- Medical Imaging, McGill University Health Centre, Montréal, Québec, Canada.
- Department of Diagnostic Radiology, McGill University, Montréal, Québec, Canada.
- Gerald Bronfman Department of Oncology, McGill University, Montréal, Québec, Canada.
- Medical Physics, McGill University Health Centre, Montréal, Québec, Canada.
ORCID-Profile: Véronique Fortier, Ives R Levesque
Förderung
- Natural Sciences and Engineering Research Council of Canada (NSERC)
- Fonds de Recherche du Québec - Santé
- Research Institute of the McGill University Health Centre
- Institut de recherche, Centre universitaire de santé McGill
Zitieren
APA
Bider, R. C., Ciobanu, C., Campos Pazmiño, J., Fortier, V., McNabb, E., & Levesque, I. R. (2026). Phase‐Sensitive Modeling Improves Fat DESPOT Multiparametric Relaxation Mapping in Fat‐Water Mixtures. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70516
Vancouver
Bider RC, Ciobanu C, Campos Pazmiño J, Fortier V, McNabb E, Levesque IR. Phase‐Sensitive Modeling Improves Fat DESPOT Multiparametric Relaxation Mapping in Fat‐Water Mixtures. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70516
BibTeX
@article{Bider2026,
author = {Bider, Renée-Claude and Ciobanu, Cristian and Campos Pazmiño, Jorge and Fortier, Véronique and McNabb, Evan and Levesque, Ives R},
title = {Phase‐Sensitive Modeling Improves Fat DESPOT Multiparametric Relaxation Mapping in Fat‐Water Mixtures},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70516}
}
EUVIMED