Early real-world implant experience with a helix-fixation ventricular leadless pacemaker
Journal of Interventional Cardiac Electrophysiology · 2024
DOI: 10.1007/s10840-024-01791-1 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, 2024. Verfasst von Devi G Nair und 11 weiteren Autor:innen. Beteiligte Einrichtung: Bernards Healthcare, Jonesboro, AR, USA. drdevignair@gmail.com. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Equipment Design. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 9 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Roughly one in six patients receiving conventional transvenous pacemaker systems experience significant complications within 1 year of implant, mainly due to the transvenous lead and subcutaneous pocket. A new helix-fixation single-chamber ventricular leadless pacemaker (LP) system capable of pre-deployment exploratory electrical mapping is commercially available. Such an LP may mitigate complications while streamlining the implantation. In this study, the initial real-world implant experience of the helix-fixation LP was evaluated following its commercial release. METHODS: In patients indicated for single-chamber right ventricular pacing, helix-fixation Aveir VR LPs (Abbott, Abbott Park, IL) were implanted using the dedicated loading tool, introducer, and delivery catheter. Implant procedural characteristics, electrical parameters, and any 30-day procedure-related adverse events of consecutive implant attempts were retrospectively evaluated. RESULTS: A total of 167 patients with Class I indication for permanent pacing received implants in four North American centers (57% male, 70 years old). Pre-fixation electrical mapping of potential sites allowed repositioning to be avoided in 95.7% of patients. Median [interquartile range] LP procedure and fluoroscopy durations were 25.5 min [20.0, 35.0] and 5.7 min [4.0, 9.2], respectively. Pacing capture threshold, sensed R-wave amplitude, and impedance were 0.8 V [0.5, 1.3], 9.0 mV [6.0, 12.0], and 705 Ω [550, 910], respectively. Implantation was successful in 98.8% of patients, with 98.2% free from acute adverse events. CONCLUSIONS: The initial, real-world experience of the helix-fixation ventricular leadless pacemaker demonstrated safe and efficient implantation with minimal repositioning, viable electrical metrics, and limited acute complications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Bernards Healthcare, Jonesboro, AR, USA. drdevignair@gmail.com.
- Arrhythmia Research Group, Jonesboro, AR, USA. drdevignair@gmail.com.
- Libin Cardiovascular Institute, Calgary, Canada.
- Icahn School of Medicine at Mount Sinai, New York, NY, USA.
- , Abbott, Sunnyvale, CA, USA.
- Bernards Healthcare, Jonesboro, AR, USA.
Zitieren
APA
Nair, D. G., Exner, D. V., Reddy, V. Y., Badie, N., Ligon, D., Miller, M. A., Lee, B., Doty, B., Thomaides, A., Eldadah, Z., Islam, M., & Hadadi, C. (2024). Early real-world implant experience with a helix-fixation ventricular leadless pacemaker. Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-024-01791-1
Vancouver
Nair DG, Exner DV, Reddy VY, Badie N, Ligon D, Miller MA, et al. Early real-world implant experience with a helix-fixation ventricular leadless pacemaker. Journal of Interventional Cardiac Electrophysiology. 2024. doi:10.1007/s10840-024-01791-1
BibTeX
@article{Nair2024,
author = {Nair, Devi G and Exner, Derek V and Reddy, Vivek Y and Badie, Nima and Ligon, David and Miller, Marc A and Lee, Bridget and Doty, Brandon and Thomaides, Athanasios and Eldadah, Zayd and Islam, Malick and Hadadi, Cyrus},
title = {Early real-world implant experience with a helix-fixation ventricular leadless pacemaker},
journal = {Journal of Interventional Cardiac Electrophysiology},
year = {2024},
doi = {10.1007/s10840-024-01791-1}
}
EUVIMED