Left Atrial Remodeling After Pacemaker Implantation Predicts Incident Atrial Fibrillation: Comparison of Leadless and Transvenous Devices
Journal of Cardiovascular Electrophysiology · 2026-06 · 37 (6) · 1230-1240
DOI: 10.1111/jce.70341 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, online erschienen am 11.04.2026. Verfasst von Naoya Inoue und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Chutoen General Medical Center, Kakegawa, Japan. Hauptthemen laut MEDLINE: Atrial Fibrillation, Atrial Remodeling, Pacemaker, Artificial, Cardiac Pacing, Artificial. Die Arbeit nennt 20 Literaturangaben.
Abstract (Originalsprache)
Background
Atrial fibrillation (AF) after pacemaker (PM) implantation is associated with adverse outcomes; however, the relationship between left atrial remodeling, device type, and ventricular pacing burden remains unclear.
Objective
We aimed to investigate (1) whether post‐implantation changes in left atrial diameter (ΔLAD) are associated with incident AF; (2) differences in AF and ΔLAD between TVP and LP; and (3) whether mean ventricular pacing percentage (Vp%) modifies device‐related effects.
Methods
This retrospective study included patients without a prior history of AF who underwent PM implantation. The primary outcome was defined as incident clinical AF, which was analyzed using Cox hazard models. Mechanistic models incorporating Vp% and paced QRS duration were also evaluated. Interaction analyses were performed using mean‐centered Vp % (device × Vp) and Vp%‐stratified analyses. To mitigate reverse causality, a landmark analysis excluding AF events within 1 year after implantation was conducted.
Results
In the pooled Cox analyses, ΔLAD was independently associated with incident AF ( p < 0.0001). No significant difference in ΔLAD was observed between the TVP and LP groups ( p = 0.417). In models adjusted for ΔLAD, LP was associated with a significantly lower risk of AF (device, p = 0.049; ΔLAD, p < 0.0001). Vp% and paced QRS duration were not significant main effects. However, a significant device × Vp interaction was observed in the mean‐centered interaction models ( p = 0.022). In landmark analyses, ΔLAD remained associated with AF beyond 1 year ( p = 0.0013).
Conclusion
Left atrial remodeling independently predicted incident AF after pacemaker implantation. LP was associated with a lower AF risk, with effects modified by the pacing burden.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Chutoen General Medical Center, Kakegawa, Japan.
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
- Department of Cardiology, Toyota Kosei Hospital, Toyota, Japan.
ORCID-Profile: Naoya Inoue
Zitieren
APA
Inoue, N., Iwata, K., Morikawa, S., & Murohara, T. (2026). Left Atrial Remodeling After Pacemaker Implantation Predicts Incident Atrial Fibrillation: Comparison of Leadless and Transvenous Devices. Journal of Cardiovascular Electrophysiology, 37(6), 1230-1240. https://doi.org/10.1111/jce.70341
Vancouver
Inoue N, Iwata K, Morikawa S, Murohara T. Left Atrial Remodeling After Pacemaker Implantation Predicts Incident Atrial Fibrillation: Comparison of Leadless and Transvenous Devices. Journal of Cardiovascular Electrophysiology. 2026;37(6):1230-1240. doi:10.1111/jce.70341
BibTeX
@article{Inoue2026,
author = {Inoue, Naoya and Iwata, Keisuke and Morikawa, Shuji and Murohara, Toyoaki},
title = {Left Atrial Remodeling After Pacemaker Implantation Predicts Incident Atrial Fibrillation: Comparison of Leadless and Transvenous Devices},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2026},
volume = {37},
number = {6},
pages = {1230--1240},
doi = {10.1111/jce.70341}
}