EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Micra Leadless and Transvenous Pacemaker: A Single‐Center Comparative Study of QRS Wave Duration Resulting From Different Pacing Sites

Yichi Yu iD, Xiaomin Yang, Xiaoming Lian, Yan Zhao, Bo Liu, Xiangfei Feng iD, Qunshan Wang, Yigang Li

Annals of Noninvasive Electrocardiology · 2025

DOI: 10.1111/anec.70050 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Annals of Noninvasive Electrocardiology, 2025. Verfasst von Yichi Yu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Electrocardiography, Cardiac Pacing, Artificial, Arrhythmias, Cardiac. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare the paced QRS duration on different sites in age‐, gender‐, and indication‐matched patients implanted with Micra leadless pacemakers and conventional transvenous pacemakers (TV‐PM).

Method

A total of 82 patients from Xinhua Hospital, Shanghai Jiaotong University, were enrolled, including two groups of 41 patients matched according to gender, age, and pacemaker indications, who underwent Micra and TV‐PM implantations, respectively. The baseline data of the patients, the pacing site described using three‐ and nine‐partition methods, and the paced QRS duration on 12‐lead electrocardiogram were then analyzed.

Results

Overall, patients in our population were on average 79.2 years of age and mostly male (75.6%). Atrioventricular node dysfunction was the most common indication (56.1%) for pacemaker therapy. Mid‐septum, especially Site 5, is the implantation site for most patients in both groups. Micra (145 ms) and TV‐PM (133 ms) both had the narrowest‐paced QRS at high septum, but Micra may exhibit significantly more reduced QRS duration than TV‐PM at low septum (Micra vs. TV‐PM: 143.0 [142.8–156.5] ms vs. 163.5 ± 17.5 ms, p = 0.044).

Conclusion

The narrowest‐paced QRS complex for Micra leadless pacemakers is achieved at high septum, and pacing at low septum by Micra may acquire shorter QRS duration than conventional TV‐PM.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pacemaker, ArtificialElectrocardiographyCardiac Pacing, ArtificialArrhythmias, CardiacHumansMaleFemaleAgedAged, 80 and overEquipment DesignRetrospective StudiesMiddle Aged

Stichwörter der Autor:innen

Clinical: Electrophysiology—conduction disturbancesClinical: Implantable devices—pacemaker‐bradyarrhythmiasClinical: Implantable devices—physiologic pacingClinical: Non‐invasive techniques ‐ electrocardiography

Autor:innen und Institutionen

  • Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.

ORCID-Profile: Yichi Yu, Xiangfei Feng

Zitieren

APA

Yu, Y., Yang, X., Lian, X., Zhao, Y., Liu, B., Feng, X., Wang, Q., & Li, Y. (2025). Micra Leadless and Transvenous Pacemaker: A Single‐Center Comparative Study of QRS Wave Duration Resulting From Different Pacing Sites. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/anec.70050

Vancouver

Yu Y, Yang X, Lian X, Zhao Y, Liu B, Feng X, et al. Micra Leadless and Transvenous Pacemaker: A Single‐Center Comparative Study of QRS Wave Duration Resulting From Different Pacing Sites. Annals of Noninvasive Electrocardiology. 2025. doi:10.1111/anec.70050

BibTeX
@article{Yu2025,
  author = {Yu, Yichi and Yang, Xiaomin and Lian, Xiaoming and Zhao, Yan and Liu, Bo and Feng, Xiangfei and Wang, Qunshan and Li, Yigang},
  title = {Micra Leadless and Transvenous Pacemaker: A Single‐Center Comparative Study of QRS Wave Duration Resulting From Different Pacing Sites},
  journal = {Annals of Noninvasive Electrocardiology},
  year = {2025},
  doi = {10.1111/anec.70050}
}
Kostenlos starten →