EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A novel EPID‐based MLC QA method with log files achieving submillimeter accuracy

Chenlu Liu, Binbing Wang, Xue Bai, Xiaolong Cheng, Xiaotong Wang, Xiaohua Yang, Guoping Shan

Journal of Applied Clinical Medical Physics · 2024

DOI: 10.1002/acm2.14450 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Chenlu Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Nuclear Science and Technology, University of South China, Hengyang, Hunan, PR China. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiotherapy Dosage, Algorithms, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, State Key Laboratory of Nuclear Reactor Systems Design for Open Projects, Research Foundation of Education Bureau of Hunan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The purpose of this study is to develop an electronic portal imaging device‐based multi‐leaf collimator calibration procedure using log files. Picket fence fields with 2–14 mm nominal strip widths were performed and normalized by open field. Normalized pixel intensity profiles along the direction of leaf motion for each leaf pair were taken. Three independent algorithms and an integration method derived from them were developed according to the valley value, valley area, full‐width half‐maximum (FWHM) of the profile, and the abutment width of the leaf pairs obtained from the log files. Three data processing schemes (Scheme A, Scheme B, and Scheme C) were performed based on different data processing methods. To test the usefulness and robustness of the algorithm, the known leaf position errors along the direction of perpendicular leaf motion via the treatment planning system were introduced in the picket fence field with nominal 5, 8, and 11 mm. Algorithm tests were performed every 2 weeks over 4 months. According to the log files, about 17.628% and 1.060% of the leaves had position errors beyond ± 0.1 and ± 0.2 mm, respectively. The absolute position errors of the algorithm tests for different data schemes were 0.062 ± 0.067 (Scheme A), 0.041 ± 0.045 (Scheme B), and 0.037 ± 0.043 (Scheme C). The absolute position errors of the algorithms developed by Scheme C were 0.054 ± 0.063 (valley depth method), 0.040 ± 0.038 (valley area method), 0.031 ± 0.031 (FWHM method), and 0.021 ± 0.024 (integrated method). For the efficiency and robustness test of the algorithm, the absolute position errors of the integration method of Scheme C were 0.020 ± 0.024 (5 mm), 0.024 ± 0.026 (8 mm), and 0.018 ± 0.024 (11 mm). Different data processing schemes could affect the accuracy of the developed algorithms. The integration method could integrate the benefits of each algorithm, which improved the level of robustness and accuracy of the algorithm. The integration method can perform multi‐leaf collimator (MLC) quality assurance with an accuracy of 0.1 mm. This method is simple, effective, robust, quantitative, and can detect a wide range of MLC leaf position errors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedRadiotherapy DosageAlgorithmsRadiotherapy, Intensity-ModulatedQuality Assurance, Health CareParticle AcceleratorsHumansCalibrationNeoplasms

Stichwörter der Autor:innen

EPIDMLC QAMLC calibrationfull‐width half‐maximum

Autor:innen und Institutionen

  • School of Nuclear Science and Technology, University of South China, Hengyang, Hunan, PR China.
  • Department of Radiation Physics, Zhejiang Cancer Hospital, Hangzhou Institute of Medicine (HIM), Chinese Academy of Sciences, Hangzhou, Zhejiang, PR China.

Förderung

  • National Natural Science Foundation of China
  • State Key Laboratory of Nuclear Reactor Systems Design for Open Projects
  • Research Foundation of Education Bureau of Hunan Province

Zitieren

APA

Liu, C., Wang, B., Bai, X., Cheng, X., Wang, X., Yang, X., & Shan, G. (2024). A novel EPID‐based MLC QA method with log files achieving submillimeter accuracy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14450

Vancouver

Liu C, Wang B, Bai X, Cheng X, Wang X, Yang X, et al. A novel EPID‐based MLC QA method with log files achieving submillimeter accuracy. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14450

BibTeX
@article{Liu2024,
  author = {Liu, Chenlu and Wang, Binbing and Bai, Xue and Cheng, Xiaolong and Wang, Xiaotong and Yang, Xiaohua and Shan, Guoping},
  title = {A novel EPID‐based MLC QA method with log files achieving submillimeter accuracy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14450}
}
Kostenlos starten →