EUVIMEDEUVIMED entdecken
Video/Audio

Robotic Arm Assisted Slow Electrode Insertion and Simultaneous Measurement of Cochlear Microphonics in Cochlear Implantation

Ioana Brill, Stefan Dazert, Stefan Hans, Stefan Brill

Journal of Visualized Experiments · 2026

DOI: 10.3791/70720 ↗

Kurz gefasst

Video/Audio in der Zeitschrift Journal of Visualized Experiments, 2026. Verfasst von Ioana Brill und 3 weiteren Autor:innen. Beteiligte Einrichtung: ENT Department of the University Clinic Bochum, St. Elisabeth Hospital; ioana.brill@rub.de. Hauptthemen laut MEDLINE: Cochlear Implantation, Robotic Surgical Procedures, Cochlear Microphonic Potentials. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cochlear microphonic potentials (CMPs) are an electrical response predominantly of the outer and, to a smaller degree, the inner hair cells to acoustic signals. They can be used to monitor hearing and structure preservation during cochlear implantation. Among other precautions, slow and steady electrode insertion has proven beneficial in this regard. In this article, the authors present a combination of robotic-assisted implantation and observation of CMPs. CMPs are recorded through the cochlear implant tip electrode before and after opening the round window membrane, during insertion, and in the final electrode position. Acoustic pure tones at frequencies determined by the patient's hearing status are used as stimuli. To set the electrode insertion trajectory, a 5-degree-of-freedom manipulator (2 rotational, 3 translational) is used. Electrode insertion is performed with a linear actuator controlled by the surgeon. Additionally, the electrode entrance can be manually guided, and the trajectory readjusted accordingly based on CMP observations. Experiences so far indicate that human-guided robotic CI electrode insertion, combined with simultaneous CMP measurement, is feasible and appears to be a promising strategy to improve cochlear structure preservation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cochlear ImplantationRobotic Surgical ProceduresCochlear Microphonic PotentialsHumansCochlear ImplantsElectrodes, Implanted

Autor:innen und Institutionen

  • ENT Department of the University Clinic Bochum, St. Elisabeth Hospital; ioana.brill@rub.de.
  • ENT Department of the University Clinic Bochum, St. Elisabeth Hospital.
  • Med-El GmbH.

Zitieren

APA

Brill, I., Dazert, S., Hans, S., & Brill, S. (2026). Robotic Arm Assisted Slow Electrode Insertion and Simultaneous Measurement of Cochlear Microphonics in Cochlear Implantation. Journal of Visualized Experiments. https://doi.org/10.3791/70720

Vancouver

Brill I, Dazert S, Hans S, Brill S. Robotic Arm Assisted Slow Electrode Insertion and Simultaneous Measurement of Cochlear Microphonics in Cochlear Implantation. Journal of Visualized Experiments. 2026. doi:10.3791/70720

BibTeX
@article{Brill2026,
  author = {Brill, Ioana and Dazert, Stefan and Hans, Stefan and Brill, Stefan},
  title = {Robotic Arm Assisted Slow Electrode Insertion and Simultaneous Measurement of Cochlear Microphonics in Cochlear Implantation},
  journal = {Journal of Visualized Experiments},
  year = {2026},
  doi = {10.3791/70720}
}
Kostenlos starten →