EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of manual and robot-assisted electrode placement in malformed cochleae using imaging-based patient specific 3D models

Fiona Anna Molnár, Mária Matuz, Zoltán Tobiás, Zsolt Geretovszky, Zsófia Bere, Haadi Mollabux, Roland Nagy, László Rovó, Ádám Perenyi

European Archives of Oto-Rhino-Laryngology · 2026-10 · 283 (12) · 7889-7903

DOI: 10.1007/s00405-026-10611-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Archives of Oto-Rhino-Laryngology, online erschienen am 19.09.2026. Verfasst von Fiona Anna Molnár und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology, Head and Neck Surgery, University of Szeged, Szeged, Hungary. drmolnarfiona@gmail.com. Hauptthemen laut MEDLINE: Cochlear Implantation, Cochlea, Imaging, Three-Dimensional, Robotic Surgical Procedures. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Szeged.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Cochlear implantation in congenital inner ear malformations can be technically challenging due to the atypical anatomy which can limit electrode selection, trajectory, and insertion depth. Although high-resolution CT/MRI and planning tools (e.g., OTOPLAN ® ) support preoperative assessment, severe malformations may require additional validation. We evaluated whether robot-assisted insertion improves insertion performance in malformed cochleae using patient-specific 3D models.

Methods

High-resolution CT and/or MRI from 8 paediatric candidates were used to reconstruct and 3D print 16 cochleae (malformed cochleae plus one anatomically normal control with eighth nerve aplasia, as applicable). Four electrode arrays (MED-EL Medium, MED-EL Compressed, MED-EL Flex24, and Cochlear Straight) were inserted by an expert surgeon (P1), a novice surgeon (P2), and a robotic system (RobOtol ® , R1). Outcomes were insertion completeness (complete/incomplete) and ease (easy/hard). Data were analysed using Firth’s penalized logistic regression and classification tree analysis. Preoperative prediction by P1 alone versus P1 + OTOPLAN ® was compared using standard classification metrics.

Results

Electrode type and cochlear anatomy were the primary determinants of insertion outcomes. Electrode arrays with shorter active lengths (MED-EL Compressed) demonstrated higher insertion completeness in anatomically restricted malformed cochleae, whereas Flex24 and Cochlear Straight showed reduced completeness in restrictive hypoplastic cochleae. Operator identity, including robotic assistance, had minimal impact; ease was generally high. OTOPLAN ® assisted planning improved prediction performance and reduced false-negative assessments.

Conclusion

In malformed cochleae, insertion completeness was influenced primarily by cochlear morphology and electrode characteristics within the outcome measures assessed. Patient-specific 3D models provide a useful platform for electrode–anatomy compatibility assessment and preoperative planning; however, clinical validation incorporating tonotopic coverage, audiological outcomes, and objective robotic performance metrics is warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cochlear ImplantationCochleaImaging, Three-DimensionalRobotic Surgical ProceduresCochlear ImplantsHumansMagnetic Resonance ImagingTomography, X-Ray ComputedFemalePrinting, Three-DimensionalChild, PreschoolChildMaleElectrodes, ImplantedInfantModels, Anatomic

Stichwörter der Autor:innen

3D printingCochlea malformationsCochlear ImplantationMedical educationRobotic Surgery.Virtual models

Autor:innen und Institutionen

  • Department of Otorhinolaryngology, Head and Neck Surgery, University of Szeged, Szeged, Hungary. drmolnarfiona@gmail.com.
  • Institute of Clinical Pharmacy, Faculty of Pharmacy, University of Szeged, Szikra Street 8, Szeged, Hungary.
  • Institute of Clinical Pharmacy, Albert Szent-Györgyi Health Center, University of Szeged, Semmelweis Street 6-8, Szeged, Hungary.
  • Department of Otorhinolaryngology, Head and Neck Surgery, University of Szeged, Szeged, Hungary.
  • 3D Centre, Interdisciplinary Research, Development, and Innovation Excellence Center, University of Szeged, Szeged, Hungary.
  • Department of Radiology, Faculty of Medicine, University of Szeged, Szeged, Hungary.

Förderung

  • University of Szeged

Zitieren

APA

Molnár, F. A., Matuz, M., Tobiás, Z., Geretovszky, Z., Bere, Z., Mollabux, H., Nagy, R., Rovó, L., & Perenyi, Á. (2026). Evaluation of manual and robot-assisted electrode placement in malformed cochleae using imaging-based patient specific 3D models. European Archives of Oto-Rhino-Laryngology, 283(12), 7889-7903. https://doi.org/10.1007/s00405-026-10611-3

Vancouver

Molnár FA, Matuz M, Tobiás Z, Geretovszky Z, Bere Z, Mollabux H, et al. Evaluation of manual and robot-assisted electrode placement in malformed cochleae using imaging-based patient specific 3D models. European Archives of Oto-Rhino-Laryngology. 2026;283(12):7889-7903. doi:10.1007/s00405-026-10611-3

BibTeX
@article{Molnr2026,
  author = {Molnár, Fiona Anna and Matuz, Mária and Tobiás, Zoltán and Geretovszky, Zsolt and Bere, Zsófia and Mollabux, Haadi and Nagy, Roland and Rovó, László and Perenyi, Ádám},
  title = {Evaluation of manual and robot-assisted electrode placement in malformed cochleae using imaging-based patient specific 3D models},
  journal = {European Archives of Oto-Rhino-Laryngology},
  year = {2026},
  volume = {283},
  number = {12},
  pages = {7889--7903},
  doi = {10.1007/s00405-026-10611-3}
}
Kostenlos starten →