EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Robotic‐Assisted Electrode Array Insertion Improves Rates of Hearing Preservation

Uzair A Khan, Camille C Dunn iD, Rachel A Scheperle iD, Jacob Oleson, Alexander D Claussen iD, Bruce J Gantz, Marlan R Hansen iD

The Laryngoscope · 2025-11 · 135 (11) · 4364-4371

DOI: 10.1002/lary.32318 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Laryngoscope, online erschienen am 11.06.2025. Verfasst von Uzair A Khan und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology - Head and Neck Surgery, University of Iowa Health Care, Iowa City, Iowa, USA. Hauptthemen laut MEDLINE: Cochlear Implantation, Robotic Surgical Procedures, Cochlear Implants, Hearing. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIDCD NIH HHS, NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective(s) Robotic‐assisted electrode array (EA) insertion is a promising technique that may enhance hearing preservation in cochlear implant (CI) surgery. The purpose of our study is to understand the extent to which robotic‐assisted EA insertion improves hearing preservation.

Methods

Twenty‐four adult patients underwent CI surgery with manual EA insertion and 27 adult patients underwent CI surgery with robotic‐assisted EA insertion using the iotaSOFT system. The EAs used included the Flex 20/24/26. The primary outcome variable was low frequency pure‐tone average (LFPTA), defined as mean audiometric threshold at 125, 250, and 500 Hz. This was measured preoperatively, at initial activation (within 4 weeks of surgery), and subsequently at 2 weeks, 3 months, 6 months, and 1 year. Functional acoustic hearing was defined as LFPTA < 80 dB HL.

Results

Seventeen out of 24 patients (71%) in the manual insertion group and 23 out of 27 patients (85%) in the robotic‐assisted EA insertion group had preserved functional acoustic hearing (< 80 dB HL) up till 1 year (Fisher's exact test (two‐tailed) is not statistically significant, p = 0.31). The number needed to treat with robotic‐assisted EA insertion to prevent one additional negative outcome of loss of functional acoustic hearing would be 7 (1/0.14).

Conclusion

Robotic‐assisted EA insertion is associated with improved hearing preservation over 1 year compared with manual insertion. Hearing preservation leads to improved outcomes and therefore every effort should be made to preserve the delicate structure and function of the cochlea during EA insertion. Robotic‐assisted EA insertion advances that objective. Level of Evidence: III (cohort study).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cochlear ImplantationRobotic Surgical ProceduresCochlear ImplantsHearingElectrodes, ImplantedHearing LossHumansMaleMiddle AgedFemaleAgedAdultTreatment OutcomeAudiometry, Pure-Tone

Stichwörter der Autor:innen

cochlear implanthearing preservationrobotic‐assisted insertion

Autor:innen und Institutionen

  • Department of Otolaryngology - Head and Neck Surgery, University of Iowa Health Care, Iowa City, Iowa, USA.
  • Department of Biostatistics, University of Iowa, Iowa City, Iowa, USA.

ORCID-Profile: Camille C Dunn, Rachel A Scheperle, Alexander D Claussen, Marlan R Hansen

Förderung

  • NIDCD NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Khan, U. A., Dunn, C. C., Scheperle, R. A., Oleson, J., Claussen, A. D., Gantz, B. J., & Hansen, M. R. (2025). Robotic‐Assisted Electrode Array Insertion Improves Rates of Hearing Preservation. The Laryngoscope, 135(11), 4364-4371. https://doi.org/10.1002/lary.32318

Vancouver

Khan UA, Dunn CC, Scheperle RA, Oleson J, Claussen AD, Gantz BJ, et al. Robotic‐Assisted Electrode Array Insertion Improves Rates of Hearing Preservation. The Laryngoscope. 2025;135(11):4364-4371. doi:10.1002/lary.32318

BibTeX
@article{Khan2025,
  author = {Khan, Uzair A and Dunn, Camille C and Scheperle, Rachel A and Oleson, Jacob and Claussen, Alexander D and Gantz, Bruce J and Hansen, Marlan R},
  title = {Robotic‐Assisted Electrode Array Insertion Improves Rates of Hearing Preservation},
  journal = {The Laryngoscope},
  year = {2025},
  volume = {135},
  number = {11},
  pages = {4364--4371},
  doi = {10.1002/lary.32318}
}
Kostenlos starten →