EUVIMEDEUVIMED entdecken
Vergleichsstudie

Robot-assisted vs. manual cochlear implant electrode array insertion in four children

Vittoria Sykopetrites, Eleonora Sica, Raffaella Moalli, Davide Cocozza, Sergio Razza, Eliana Cristofari

European Archives of Oto-Rhino-Laryngology · 2025

DOI: 10.1007/s00405-024-09195-7 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift European Archives of Oto-Rhino-Laryngology, 2025. Verfasst von Vittoria Sykopetrites und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Audiovestibology, ASST dei Sette Laghi, Via Lazio, 21100, Varese, VA, Italy. v.sykopetrites@gmail.com. Hauptthemen laut MEDLINE: Cochlear Implantation, Cochlear Implants, Robotic Surgical Procedures. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Evaluate the feasibility and safety of a robotic electrode insertion in pediatric cochlear implantation and compare the results with manually inserted electrodes in the same subject. METHODS: Retrospective case series review of four children who underwent bilateral cochlear implantation with the same array: on one side, the array was inserted using the robot, while on the other side the array was inserted manually. Behavioural and electrophysiological measures were compared. RESULTS: The duration of surgery when the robot was adopted was significantly longer than when a manual insertion was performed (161.15 ± 27.59 minutes vs. 122.6 ± 37.71 min, paired t-test: p = 0.029). Moreover, robotic electrode insertion was significantly slower (average insertion speed 0.3 mm/second vs. 0.52 ± 0.17 mm/s, paired t-test: p = 0.0055). On radiologic examination, none of the arrays was misplaced. Impedance, both at activation and at one year of cochlear implant use, was significantly lower on the robotic side in monopolar mode compared to the manual side (mean 9.64 ± 2.41kΩ and 9.97 ± 1.39 kΩ vs. 10.43 ± 2.69 kΩ and 10.94 ± 1.11 kΩ, paired t test, p = 0.0251 and p = 0.0061, respectively). Both the threshold stimulation level and the most comfortable loud stimulation level were significantly lower in the robotic inserted ear compared to the manually inserted ear (mean 108.1 ± 5.98 and 169 ± 4.84 vs. 112.1 ± 7.43 and 172.7 ± 6.83, respectively, paired t test p < 0.0001). CONCLUSIONS: Although we present a small group of cases, our results show how robot-based array insertion is associated with lower impedance and stimulation levels compared to manually inserted arrays.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cochlear ImplantationCochlear ImplantsRobotic Surgical ProceduresHumansRetrospective StudiesMaleFemaleChild, PreschoolFeasibility StudiesChildElectrodes, ImplantedInfantOperative Time

Stichwörter der Autor:innen

Cochlear implantImpedanceInsertionPediatric cochlear implantRobot

Autor:innen und Institutionen

  • Department of Audiovestibology, ASST dei Sette Laghi, Via Lazio, 21100, Varese, VA, Italy. v.sykopetrites@gmail.com.
  • Department of Audiovestibology, ASST dei Sette Laghi, Via Lazio, 21100, Varese, VA, Italy.

Zitieren

APA

Sykopetrites, V., Sica, E., Moalli, R., Cocozza, D., Razza, S., & Cristofari, E. (2025). Robot-assisted vs. manual cochlear implant electrode array insertion in four children. European Archives of Oto-Rhino-Laryngology. https://doi.org/10.1007/s00405-024-09195-7

Vancouver

Sykopetrites V, Sica E, Moalli R, Cocozza D, Razza S, Cristofari E. Robot-assisted vs. manual cochlear implant electrode array insertion in four children. European Archives of Oto-Rhino-Laryngology. 2025. doi:10.1007/s00405-024-09195-7

BibTeX
@article{Sykopetrites2025,
  author = {Sykopetrites, Vittoria and Sica, Eleonora and Moalli, Raffaella and Cocozza, Davide and Razza, Sergio and Cristofari, Eliana},
  title = {Robot-assisted vs. manual cochlear implant electrode array insertion in four children},
  journal = {European Archives of Oto-Rhino-Laryngology},
  year = {2025},
  doi = {10.1007/s00405-024-09195-7}
}
Kostenlos starten →