EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Implant Macrodesign on Primary Stability Across Different Bone Density Models: A Comparative In Vitro Study

Lidija Veljkovic, Miljana Nedeljkovic, Jovana Milanovic, Aleksandra Arnaut, Momir Stevanovic, Gvozden Rosic, Dragica Selakovic, Nemanja Jovicic, Pavle Milanovic

Journal of Functional Biomaterials · 03.11.2026 · 17 (11) · 568

DOI: 10.3390/jfb17110568 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Functional Biomaterials, online erschienen am 03.11.2026. Verfasst von Lidija Veljkovic und 8 weiteren Autor:innen. Die Arbeit nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Implant macrogeometry and bone density are major determinants of primary stability. This study aimed to evaluate primary stability across different implant macrodesigns and block models. Materials and Methods: A total of 153 implants were divided into Group 1 (AnyRidge), Group 2 (BlueDiamond RC), and Group 3 (BlueDiamond NC) (n = 51 each). Each implant was sequentially tested in synthetic D1–D4 bone models. Insertion torque values (ITV) and implant stability quotient (ISQ) were recorded.

Results

In D1, ITV was highest in Group 1 (69.51 ± 1.50 Ncm), followed by Group 2 (53.82 ± 6.75 Ncm) and Group 3 (49.31 ± 7.00 Ncm) (p < 0.01, p < 0.001). In D4, ITV decreased to 34.71 ± 3.23, 19.90 ± 3.08, and 11.18 ± 2.14 Ncm, respectively (p < 0.001). D1 ISQ values were 84.53 ± 2.51, 72.08 ± 3.69, and 66.33 ± 2.63, respectively (p < 0.001). In D4, ISQ values were 60.29 ± 3.84, 52.86 ± 3.73, and 52.18 ± 2.48, respectively (p < 0.001); Groups 2 and 3 did not differ significantly.

Conclusions

Implant macrodesign influences primary stability, with AnyRidge demonstrating the highest ITV and ISQ values in D1 as well as D4. Further clinical studies would be beneficial to support these findings.

Zitieren

APA

Veljkovic, L., Nedeljkovic, M., Milanovic, J., Arnaut, A., Stevanovic, M., Rosic, G., Selakovic, D., Jovicic, N., & Milanovic, P. (2026). Influence of Implant Macrodesign on Primary Stability Across Different Bone Density Models: A Comparative In Vitro Study. Journal of Functional Biomaterials, 17(11), 568. https://doi.org/10.3390/jfb17110568

Vancouver

Veljkovic L, Nedeljkovic M, Milanovic J, Arnaut A, Stevanovic M, Rosic G, et al. Influence of Implant Macrodesign on Primary Stability Across Different Bone Density Models: A Comparative In Vitro Study. Journal of Functional Biomaterials. 2026;17(11):568. doi:10.3390/jfb17110568

BibTeX
@article{Veljkovic2026,
  author = {Veljkovic, Lidija and Nedeljkovic, Miljana and Milanovic, Jovana and Arnaut, Aleksandra and Stevanovic, Momir and Rosic, Gvozden and Selakovic, Dragica and Jovicic, Nemanja and Milanovic, Pavle},
  title = {Influence of Implant Macrodesign on Primary Stability Across Different Bone Density Models: A Comparative In Vitro Study},
  journal = {Journal of Functional Biomaterials},
  year = {2026},
  volume = {17},
  number = {11},
  pages = {568},
  doi = {10.3390/jfb17110568}
}
Kostenlos starten →