Correlation of two different devices for the evaluation of primary implant stability depending on dental implant length and bone density: An in vitro study
PLOS ONE · 22.05.2024 · 19 (5) · e0290595
DOI: 10.1371/journal.pone.0290595 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 22.05.2024. Verfasst von Jungwon Lee und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dental Biomaterials Science, School of Dentistry, Dental Research Institute, Seoul National University, Seoul, 03080, Republic of Korea. Hauptthemen laut MEDLINE: Bone Density, Dental Implants. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Medical Device Development Fund.
Abstract (Originalsprache)
Non-invasive objective implant stability measurements are needed to determine the appropriate timing of prosthetic fitting after implant placement. We compared the early implant stability results obtained using resonance frequency analysis (RFA) and damping capacity analysis (DCA) depending on the implant length and bone density. Total 60, 4.0 mm diameter implants of various lengths (7.3 mm, 10 mm, and 13 mm) were used. In Group I, low-density bone was described using 15 PCF (0.24 g/cm3) polyurethane bone blocks, and in Group II, 30 PCF (0.48 g/cm3) polyurethane bone blocks were used to describe medium density bone. RFA was performed using an Osstell ® Beacon+; DCA was performed using Anycheck ® . Measurements were repeated five times for each implant. Statistical significance was set at P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Dental Biomaterials Science, School of Dentistry, Dental Research Institute, Seoul National University, Seoul, 03080, Republic of Korea.
- Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea.
- Dental Life Science Research Institute, Seoul National University Dental Hospital, Seoul, Republic of Korea.
- Department of Prosthodontics, Gwanak Center, Seoul National University Dental Hospital, Seoul, Republic of Korea.
ORCID-Profile: Jungwon Lee, Bongju Kim, Yeon-Wha Baek
Förderung
- Korea Medical Device Development Fund
Zitieren
APA
Lee, J., Lim, Y. J., Ahn, J. S., Kim, B., Baek, Y. W., & Lim, B. S. (2024). Correlation of two different devices for the evaluation of primary implant stability depending on dental implant length and bone density: An in vitro study. PLOS ONE, 19(5), e0290595. https://doi.org/10.1371/journal.pone.0290595
Vancouver
Lee J, Lim YJ, Ahn JS, Kim B, Baek YW, Lim BS. Correlation of two different devices for the evaluation of primary implant stability depending on dental implant length and bone density: An in vitro study. PLOS ONE. 2024;19(5):e0290595. doi:10.1371/journal.pone.0290595
BibTeX
@article{Lee2024,
author = {Lee, Jungwon and Lim, Young-Jun and Ahn, Jin-Soo and Kim, Bongju and Baek, Yeon-Wha and Lim, Bum-Soon},
title = {Correlation of two different devices for the evaluation of primary implant stability depending on dental implant length and bone density: An in vitro study},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {5},
pages = {e0290595},
doi = {10.1371/journal.pone.0290595}
}