Assessing a Stimulator Modification for Simultaneous Noninvasive Auricular Vagus Nerve Stimulation and MRI

Vanessa Teckentrup iD, Mareike Ludwig, Janis Seibt, Renée Hartig, Hubert Preissl, Mark Schuppert, Nikolai I Avdievich, Klaus Scheffler, Nikos Priovoulos, Maik Ehses, Benedikt A Poser, Christopher J Wiggins and 6 more

Journal of Neuroimaging · 2025

DOI: 10.1111/jon.70098 ↗

At a glance

Übersichtsarbeit in Journal of Neuroimaging, 2025. Written by Vanessa Teckentrup and 17 co-authors. Institution: Department of Psychiatry and Psychotherapy, University of Tübingen, Tübingen, Germany. Major MEDLINE topics: Magnetic Resonance Imaging, Vagus Nerve Stimulation, Vagus Nerve, Transcutaneous Electric Nerve Stimulation. 59 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: Deutsche Forschungsgemeinschaft, NIMH NIH HHS, NIH HHS.

ResumoSubjectsDados bibliográficosCiteRelated studies

Abstract (original language)

Background and Purpose The vagus nerve can be stimulated noninvasively at the ear using transcutaneous auricular vagus nerve stimulation (taVNS). Concurrent functional MRI (fMRI) permits study of taVNS‐induced changes in brain dynamics, a key requisite for precision neurostimulation. However, there is no standardized protocol for how to safely apply taVNS during MRI. One major risk is temperature increase exceeding innocuous thresholds due to coupling of the emitted radio frequency (RF) pulse during imaging. Thus, we developed and tested a stimulator cable configuration with floating ground cable traps and filter plate connectors.

Methods

We measured temperature, resonance of the stimulation electrodes, and current interference using unmodified and modified stimulation cables. Measurements were conducted across three sites using different 3T MRI scanner models, stimulators, and stimulation strengths with phantoms and human participants.

Results

The modified compared to the unmodified cable considerably reduced RF heating as the relative temperature increase stayed well below the 2 K threshold specified by the ASTM F2182 standard. Additionally, in accordance with ASTM 2119, we can rule out potential distortion and signal loss around the electrodes due to current flow from the stimulator and demonstrate that impaired image quality in brainstem and midbrain regions is recovered using the modified cable.

Conclusions

We show that adding floating ground cable traps to the stimulator cable allows the safe use of taVNS with fMRI and may improve image quality in functional imaging. To enable other researchers to modify their hardware in the same way, we provide details of the modifications.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingVagus Nerve StimulationVagus NerveTranscutaneous Electric Nerve StimulationBrainHumansEquipment DesignPhantoms, ImagingMaleFemaleAdult

Author keywords

MRIRFelectrical stimulationneuroimagingtaVNStemperaturevagus nerve

Authors and institutions

  • Department of Psychiatry and Psychotherapy, University of Tübingen, Tübingen, Germany.
  • School of Psychology, Trinity College Dublin, Dublin, Ireland.
  • Institute of Cognitive Neurology and Dementia Research, Otto-von-Guericke University Magdeburg, Magdeburg, Germany.
  • Department of Neurology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • German Center for Neurodegenerative Diseases (DZNE), Magdeburg, Germany.
  • Department of Biomedical Magnetic Resonance, Otto-von-Guericke University Magdeburg, Magdeburg, Germany.

ORCID profiles: Vanessa Teckentrup

Funding

  • Deutsche Forschungsgemeinschaft
  • NIMH NIH HHS
  • NIH HHS
  • Toegepaste en Technische Wetenschappen, NWO
  • NIA NIH HHS
  • European Union Horizon 2020
  • University of Tübingen, Faculty of Medicine fortüne entry
  • Alzheimer's Research UK

Cite

APA

Teckentrup, V., Ludwig, M., Seibt, J., Hartig, R., Preissl, H., Schuppert, M., Avdievich, N. I., Scheffler, K., Priovoulos, N., Ehses, M., Poser, B. A., Wiggins, C. J., Trautner, P., Honerbach, W., Jacobs, H. I. L., Speck, O., Hämmerer, D., & Kroemer, N. B. (2025). Assessing a Stimulator Modification for Simultaneous Noninvasive Auricular Vagus Nerve Stimulation and MRI. Journal of Neuroimaging. https://doi.org/10.1111/jon.70098

Vancouver

Teckentrup V, Ludwig M, Seibt J, Hartig R, Preissl H, Schuppert M, et al. Assessing a Stimulator Modification for Simultaneous Noninvasive Auricular Vagus Nerve Stimulation and MRI. Journal of Neuroimaging. 2025. doi:10.1111/jon.70098

BibTeX
@article{Teckentrup2025,
  author = {Teckentrup, Vanessa and Ludwig, Mareike and Seibt, Janis and Hartig, Renée and Preissl, Hubert and Schuppert, Mark and Avdievich, Nikolai I and Scheffler, Klaus and Priovoulos, Nikos and Ehses, Maik and Poser, Benedikt A and Wiggins, Christopher J and Trautner, Peter and Honerbach, Walter and Jacobs, Heidi I L and Speck, Oliver and Hämmerer, Dorothea and Kroemer, Nils B},
  title = {Assessing a Stimulator Modification for Simultaneous Noninvasive Auricular Vagus Nerve Stimulation and MRI},
  journal = {Journal of Neuroimaging},
  year = {2025},
  doi = {10.1111/jon.70098}
}
Start for free →