Fast, high-quality, and unshielded 0.2 T low-field mobile MRI using minimal hardware resources
Magnetic Resonance Materials in Physics, Biology and Medicine · 2024
DOI: 10.1007/s10334-024-01184-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, 2024. Verfasst von Lei Li und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Electrical Engineering Chinese Academy of Sciences, Beijing, China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Phantoms, Imaging, Brain, Deep Learning. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
OBJECTIVE: To propose a deep learning-based low-field mobile MRI strategy for fast, high-quality, unshielded imaging using minimal hardware resources. METHODS: Firstly, we analyze the correlation of EMI signals between the sensing coil and the MRI coil to preliminarily verify the feasibility of active EMI shielding using a single sensing coil. Then, a powerful deep learning EMI elimination model is proposed, which can accurately predict the EMI components in the MRI coil signals using EMI signals from at least one sensing coil. Further, deep learning models with different task objectives (super-resolution and denoising) are strategically stacked for multi-level post-processing to enable fast and high-quality low-field MRI. Finally, extensive phantom and brain experiments were conducted on a home-built 0.2 T mobile brain scanner for the evaluation of the proposed strategy. RESULTS: 20 healthy volunteers were recruited to participate in the experiment. The results show that the proposed strategy enables the 0.2 T scanner to generate images with sufficient anatomical information and diagnostic value under unshielded conditions using a single sensing coil. In particular, the EMI elimination outperforms the state-of-the-art deep learning methods and numerical computation methods. In addition, 2 × super-resolution (DDSRNet) and denoising (SwinIR) techniques enable further improvements in imaging speed and quality. DISCUSSION: The proposed strategy enables low-field mobile MRI scanners to achieve fast, high-quality imaging under unshielded conditions using minimal hardware resources, which has great significance for the widespread deployment of low-field mobile MRI scanners.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Electrical Engineering Chinese Academy of Sciences, Beijing, China.
- University of Chinese Academy of Sciences, Beijing, China.
- Department of Radiology, Peking University Third Hospital, Beijing, China.
- Institute of Electrical Engineering Chinese Academy of Sciences, Beijing, China. yangwenh@mail.iee.ac.cn.
- University of Chinese Academy of Sciences, Beijing, China. yangwenh@mail.iee.ac.cn.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Li, L., He, Q., Wei, S., Wang, H., Wang, Z., Wei, Z., He, H., Xiang, C., & Yang, W. (2024). Fast, high-quality, and unshielded 0.2 T low-field mobile MRI using minimal hardware resources. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-024-01184-5
Vancouver
Li L, He Q, Wei S, Wang H, Wang Z, Wei Z, et al. Fast, high-quality, and unshielded 0.2 T low-field mobile MRI using minimal hardware resources. Magnetic Resonance Materials in Physics, Biology and Medicine. 2024. doi:10.1007/s10334-024-01184-5
BibTeX
@article{Li2024,
author = {Li, Lei and He, Qingyuan and Wei, Shufeng and Wang, Huixian and Wang, Zheng and Wei, Zhao and He, Hongyan and Xiang, Ce and Yang, Wenhui},
title = {Fast, high-quality, and unshielded 0.2 T low-field mobile MRI using minimal hardware resources},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2024},
doi = {10.1007/s10334-024-01184-5}
}
EUVIMED