Flexible metasurface for improving brain imaging at 7T
Magnetic Resonance in Medicine · 2024-08 · 92 (2) · 869-880
DOI: 10.1002/mrm.30088 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 12.03.2024. Verfasst von Vladislav Koloskov und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Physics and Engineering, ITMO University, St. Petersburg, Russia. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Signal-To-Noise Ratio. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: Russian Science Foundation, State assignment within the framework of the national project "Science and Universities", Ministry of Science and Higher Education of the Russian Federation.
Abstract (Originalsprache)
Purpose
Ultra‐high field MRI offers unprecedented detail for noninvasive visualization of the human brain. However, brain imaging is challenging at 7T due to the B field inhomogeneity, which results in signal intensity drops in temporal lobes and a bright region in the brain center. This study aims to evaluate using a metasurface to improve brain imaging at 7T and simplify the investigative workflow.
Methods
Two flexible metasurfaces comprising a periodic structure of copper strips and parallel‐plate capacitive elements printed on an ultra‐thin substrate were optimized for brain imaging and implemented via PCB. We considered two setups: (1) two metasurfaces located near the temporal lobes and (2) one metasurface placed near the occipital lobe. The effect of metasurface placement on the transmit efficiency and specific absorption rate was evaluated via electromagnetic simulation studies with voxelized models. In addition, their impact on signal‐to‐noise ratio (SNR) and diagnostic image quality was assessed in vivo for two male and one female volunteers.
Results
Placement of metasurfaces near the regions of interest led to an increase in homogeneity of the transmit field by 5% and 10.5% in the right temporal lobe and occipital lobe for a male subject, respectively. SAR efficiency values changed insignificantly, dropping by less than 8% for all investigated setups. In vivo studies also confirmed the numerically predicted improvement in field distribution and receive sensitivity in the desired ROI.
Conclusion
Optimized metasurfaces enable homogenizing transmit field distribution in the brain at 7T. The proposed lightweight and flexible structure can potentially provide MR examination with higher diagnostic value images.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Physics and Engineering, ITMO University, St. Petersburg, Russia.
- Magnetic Detection & Imaging Group, TechMed Centre, University of Twente, Enschede, The Netherlands.
- C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.
ORCID-Profile: Vladislav Koloskov, Wyger M Brink, Andrew G Webb, Alena Shchelokova
Förderung
- Russian Science Foundation
- State assignment within the framework of the national project "Science and Universities"
- Ministry of Science and Higher Education of the Russian Federation
Zitieren
APA
Koloskov, V., Brink, W. M., Webb, A. G., & Shchelokova, A. (2024). Flexible metasurface for improving brain imaging at 7T. Magnetic Resonance in Medicine, 92(2), 869-880. https://doi.org/10.1002/mrm.30088
Vancouver
Koloskov V, Brink WM, Webb AG, Shchelokova A. Flexible metasurface for improving brain imaging at 7T. Magnetic Resonance in Medicine. 2024;92(2):869-880. doi:10.1002/mrm.30088
BibTeX
@article{Koloskov2024,
author = {Koloskov, Vladislav and Brink, Wyger M and Webb, Andrew G and Shchelokova, Alena},
title = {Flexible metasurface for improving brain imaging at 7T},
journal = {Magnetic Resonance in Medicine},
year = {2024},
volume = {92},
number = {2},
pages = {869--880},
doi = {10.1002/mrm.30088}
}
EUVIMED