Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 12.03.2024. Verfasst von Paul S Jacobs und 10 weiteren Autor:innen. Beteiligte Einrichtung: Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Phantoms, Imaging, Equipment Design. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIA NIH HHS, National Institute of Aging.
Abstract (Originalsprache)
Purpose
Ultrahigh field (≥7 T) MRI is at the cutting edge of medical imaging, enabling enhanced spatial and spectral resolution as well as enhanced susceptibility contrast. However, transmit () field inhomogeneity due to standing wave effects caused by the shortened RF wavelengths at 7 T is still a challenge to overcome. Novel hardware methods such as dielectric pads have been shown to improve the field inhomogeneity but are currently limited in their corrective effect by the range of high‐permittivity materials available and have a fixed shelf life. In this work, an optimized metasurface design is presented that demonstrates in vivo enhancement of the field.
Methods
A prototype metasurface was optimized by an empirical capacitor sweep and by varying the period size. Phantom temperature experiments were performed to evaluate potential metasurface heating effects during scanning. Lastly, in vivo gradient echo images and maps were acquired on five healthy subjects on a 7 T system. Dielectric pads were also used as a comparison throughout the work as a standard comparison.
Results
The metasurfaces presented here enhanced the average relative SNR of the gradient echo images by a factor of 2.26 compared to the dielectric pads factor of 1.61. Average values reflected a similar enhancement of 27.6% with the metasurfaces present versus 8.9% with the dielectric pads.
Conclusion
The results demonstrate that metasurfaces provide superior performance to dielectric padding as shown by maps reflecting their direct effects and resulting enhancements in image SNR at 7 T.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
- Magnetic Detection and Imaging group, TechMed Centre, University of Twente, Enschede, The Netherlands.
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
- Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
ORCID-Profile: Paul S Jacobs, Wyger Brink, M Dylan Tisdall, Ravi Prakash Reddy Nanga
Förderung
- NIBIB NIH HHS
- NIA NIH HHS
- National Institute of Aging
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Jacobs, P. S., Wilson, N., Brink, W., Swain, A., Armbruster, R., Hanumapur, A., Tisdall, M. D., Detre, J., Nanga, R. P. R., Elliott, M. A., & Reddy, R. (2024). In vivo B1+ enhancement of calf MRI at 7 T via optimized flexible metasurfaces. Magnetic Resonance in Medicine, 92(3), 1277-1289. https://doi.org/10.1002/mrm.30060
Vancouver
Jacobs PS, Wilson N, Brink W, Swain A, Armbruster R, Hanumapur A, et al. In vivo B1+ enhancement of calf MRI at 7 T via optimized flexible metasurfaces. Magnetic Resonance in Medicine. 2024;92(3):1277-1289. doi:10.1002/mrm.30060
BibTeX
@article{Jacobs2024,
author = {Jacobs, Paul S and Wilson, Neil and Brink, Wyger and Swain, Anshuman and Armbruster, Ryan and Hanumapur, Aniketh and Tisdall, M Dylan and Detre, John and Nanga, Ravi Prakash Reddy and Elliott, Mark A and Reddy, Ravinder},
title = {In vivo B1+ enhancement of calf MRI at 7 T via optimized flexible metasurfaces},
journal = {Magnetic Resonance in Medicine},
year = {2024},
volume = {92},
number = {3},
pages = {1277--1289},
doi = {10.1002/mrm.30060}
}
EUVIMED