EUVIMEDEUVIMED entdecken
Crossref

Study on the 241Am-Be neutron reference radiation field established at CAEP

Song Zhang iD, Da-Jie Ding, Ben-Jiang Mao, Ren-Hong Zhuo, Jing Cheng, Hui Zheng, Ji-Lu Lv, Yi-Xin Liu

Radiation Protection Dosimetry · 2025

DOI: 10.1093/rpd/ncaf094 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2025. Verfasst von Song Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, No. 64, Mianshan Road, Youxian District, Mianyang 621999, Sichuan, …. Hauptthemen laut MEDLINE: Neutrons, Americium, Radiation Monitoring, Beryllium. Die Arbeit nennt 27 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In order to evaluate the field characteristics and instrument calibration capability of the 241Am-Be neutron reference radiation field at China Academy of Engineering Physics (CAEP), this paper conducted a series of researches on the radiation field. Firstly, the neutron energy spectrum of the field was investigated by multi-sphere spectrometer and Geant4. Secondly, the quantity transmission from China Institute of Atomic Energy (CIAE) to CAEP was achieved through the precision long counter system. In addition, three neutron dose rate meters from different manufacturers were calibrated in both the fields at CAEP and CIAE. Finally, the uncertainty of calibration factor for each instrument was calculated and validated in the two fields. The results demonstrated that the room scatter in the neutron radiation reference field at CAEP meet the requirement of ISO 8529 and the neutron energy spectrum measured in the field was acceptable. The range of neutron ambient dose equivalent rate that can be produced at CAEP and its uncertainty were determined. The calibration factors and their extended uncertainties obtained using two instruments in both fields were found to be reasonable and reliable. The radiation field established at CAEP can meet the routine calibration and experiment of common neutron dose rate meters.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NeutronsAmericiumRadiation MonitoringBerylliumRadiation ProtectionCalibrationRadiation DosageChinaHumans

Substanzen

AmericiumBerylliumAmericium-241

Autor:innen und Institutionen

  • Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, No. 64, Mianshan Road, Youxian District, Mianyang 621999, Sichuan, China.

ORCID-Profile: Song Zhang

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, S., Ding, D. J., Mao, B. J., Zhuo, R. H., Cheng, J., Zheng, H., Lv, J. L., & Liu, Y. X. (2025). Study on the 241Am-Be neutron reference radiation field established at CAEP. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf094

Vancouver

Zhang S, Ding DJ, Mao BJ, Zhuo RH, Cheng J, Zheng H, et al. Study on the 241Am-Be neutron reference radiation field established at CAEP. Radiation Protection Dosimetry. 2025. doi:10.1093/rpd/ncaf094

BibTeX
@article{Zhang2025,
  author = {Zhang, Song and Ding, Da-Jie and Mao, Ben-Jiang and Zhuo, Ren-Hong and Cheng, Jing and Zheng, Hui and Lv, Ji-Lu and Liu, Yi-Xin},
  title = {Study on the 241Am-Be neutron reference radiation field established at CAEP},
  journal = {Radiation Protection Dosimetry},
  year = {2025},
  doi = {10.1093/rpd/ncaf094}
}
Kostenlos starten →