EUVIMEDEUVIMED entdecken
Crossref

An electronic energy compensation method for flattening the energy response of SiPM-GGAG:Ce,B based gamma detector

Saurabh Srivastava iD, Pratip Mitra iD, Amit Kumar, Sunil Singh, Mohit Tyagi, Aerattukkara Vinod Kumar, Anita Topkar

Radiation Protection Dosimetry · 18.11.2024 · 200 (19) · 1879-1891

DOI: 10.1093/rpd/ncae196 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 21.09.2024. Verfasst von Saurabh Srivastava und 6 weiteren Autor:innen. Beteiligte Einrichtung: Environmental Monitoring and Assessment Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India. Hauptthemen laut MEDLINE: Algorithms, Gamma Rays. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Department of Atomic Energy, Government of India.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The energy response of gross gamma dose rate monitors needs to be flat in order to prevent overestimation of dose at low gamma energies. In this paper, a discriminator threshold modulation based electronic energy compensation algorithm has been proposed for SiPM-scintillator based gamma detectors. Theoretical simulation studies were carried out in order to optimize the parameters of the periodic ramp voltage used for modulation of the discriminator threshold of a SiPM-GGAG:Ce,B based gamma dose rate monitor. A customized threshold modulation circuit and signal processing electronics were developed for this gamma detector. For experimentally optimizing the parameters, the energy response studies of the detector, with and without the discriminator threshold modulation, were carried out. With the optimized parameters for a periodic ramp threshold, the count rates for 241Am (60 keV) and 60Co (1173 and 1332 keV) were observed to be within ±30% of the count rate obtained for 137Cs (662 keV). Using the electronic energy compensation techniques presented in this paper, a flat energy response of the SiPM-scintillator gamma detector for the energy range of 60 keV to 1.5 MeV could be achieved.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsGamma RaysEquipment DesignCesium RadioisotopesAmericiumElectronicsCobalt RadioisotopesScintillation CountingRadiation MonitoringRadiation DosageComputer SimulationHumans

Substanzen

Cesium RadioisotopesAmericiumCobalt RadioisotopesAmericium-241Cesium-137Cobalt-60

Autor:innen und Institutionen

  • Environmental Monitoring and Assessment Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India.
  • Homi Bhabha National Institute, Trombay, Mumbai 400094, India.
  • Electronics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India.
  • Radiation Safety Systems Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India.
  • Technical Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India.

ORCID-Profile: Saurabh Srivastava, Pratip Mitra

Förderung

  • Department of Atomic Energy, Government of India

Zitieren

APA

Srivastava, S., Mitra, P., Kumar, A., Singh, S., Tyagi, M., Kumar, A. V., & Topkar, A. (2024). An electronic energy compensation method for flattening the energy response of SiPM-GGAG:Ce,B based gamma detector. Radiation Protection Dosimetry, 200(19), 1879-1891. https://doi.org/10.1093/rpd/ncae196

Vancouver

Srivastava S, Mitra P, Kumar A, Singh S, Tyagi M, Kumar AV, et al. An electronic energy compensation method for flattening the energy response of SiPM-GGAG:Ce,B based gamma detector. Radiation Protection Dosimetry. 2024;200(19):1879-1891. doi:10.1093/rpd/ncae196

BibTeX
@article{Srivastava2024,
  author = {Srivastava, Saurabh and Mitra, Pratip and Kumar, Amit and Singh, Sunil and Tyagi, Mohit and Kumar, Aerattukkara Vinod and Topkar, Anita},
  title = {An electronic energy compensation method for flattening the energy response of SiPM-GGAG:Ce,B based gamma detector},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  volume = {200},
  number = {19},
  pages = {1879--1891},
  doi = {10.1093/rpd/ncae196}
}
Kostenlos starten →