Spectrometric analysis and internal dose assessment in lung counting for reactor-grade Pu compounds
Radiation Protection Dosimetry · 2025
DOI: 10.1093/rpd/ncaf114 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2025. Verfasst von Masayuki Naito und 7 weiteren Autor:innen. Beteiligte Einrichtung: National Institutes for Quantum Science and Technology (QST/NIRS), 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan. Hauptthemen laut MEDLINE: Plutonium, Lung, Radiation Monitoring, Nuclear Reactors. Die Arbeit nennt 23 Literaturangaben. Gefördert von: Japan's Nuclear Regulation Authority, Japan’s Nuclear Regulation Authority.
Abstract (Originalsprache)
Internal contamination with plutonium (Pu) isotopes represents one critical exposure scenario in nuclear fuel cycle facilities. Lung counting is commonly employed as the initial individual monitoring method following inhalation of Pu. Due to the low detection sensitivity for characteristic X-rays emitted by Pu isotopes, the γ-ray emitted by coexisting 241Am is typically used as a surrogate for measurement. However, it is essential to establish clear procedures applicable in cases of severe internal exposure. In this study, key challenges associated with lung counting and dose assessment were examined, focusing on an inhalation event of reactor-grade Pu compounds containing 238Pu to 242Pu. These challenges included: complex spectral peak analysis; increased minimum detectable activity for Pu isotopes due to interference from 241Am; and evaluation of the minimum assessable dose considering Pu isotopic composition. Based on these considerations, procedures from lung counting to internal dose assessment were refined to support emergency response.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- National Institutes for Quantum Science and Technology (QST/NIRS), 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan.
- Nagasaki University, 1-12-4 Sakamoto, Nagasaki 852-8523, Japan.
- Tokyo Metropolitan University, 7-2-10 Higashi-Ogu, Arakawa, Tokyo 116-8551, Japan.
ORCID-Profile: Masayuki Naito, Yuma Mihei, Kazuaki Yajima, Yuki Tamakuma, Eunjoo Kim, Kotaro Tani, Munehiko Kowatari, Osamu Kurihara
Förderung
- Japan's Nuclear Regulation Authority
- Japan’s Nuclear Regulation Authority
Zitieren
APA
Naito, M., Mihei, Y., Yajima, K., Tamakuma, Y., Kim, E., Tani, K., Kowatari, M., & Kurihara, O. (2025). Spectrometric analysis and internal dose assessment in lung counting for reactor-grade Pu compounds. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf114
Vancouver
Naito M, Mihei Y, Yajima K, Tamakuma Y, Kim E, Tani K, et al. Spectrometric analysis and internal dose assessment in lung counting for reactor-grade Pu compounds. Radiation Protection Dosimetry. 2025. doi:10.1093/rpd/ncaf114
BibTeX
@article{Naito2025,
author = {Naito, Masayuki and Mihei, Yuma and Yajima, Kazuaki and Tamakuma, Yuki and Kim, Eunjoo and Tani, Kotaro and Kowatari, Munehiko and Kurihara, Osamu},
title = {Spectrometric analysis and internal dose assessment in lung counting for reactor-grade Pu compounds},
journal = {Radiation Protection Dosimetry},
year = {2025},
doi = {10.1093/rpd/ncaf114}
}
EUVIMED