EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparative assessment of spherical and cylindrical ionization chambers (PTW 32002 and PTW 23361) in 60Co and 137Cs reference beams: experimental and Monte Carlo evaluation for installation compliance in gamma irradiator

Taibi Zidouz iD, Asmaa Mouhssine, Hasbiya Tamiss, Abdessamad Didi, Abdellatif Talbi, Khalid Nabaoui, Elmehdi Alibrahmi, El Mahjoub Chakir, Abdelwahab Badague, Mohamed Zaryah

Radiation Protection Dosimetry · 2026

DOI: 10.1093/rpd/ncag014 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Radiation Protection Dosimetry, 2026. Verfasst von Taibi Zidouz und 9 weiteren Autor:innen. Beteiligte Einrichtung: National Center for Energy Sciences and Nuclear Technology, CNESTEN, P.O. Box 1382, R.P. 10001, Rabat, Morocco. Hauptthemen laut MEDLINE: Cobalt Radioisotopes, Cesium Radioisotopes, Radiometry, Gamma Rays. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accredited calibration laboratories operating under ISO/IEC 17025 must demonstrate compliance of their facilities with technical standards such as ISO 4037 when performing calibrations in gamma and X-ray fields, typically using ionization chambers as reference instruments. In this framework, the accurate determination of the air-kerma rate is a critical step to ensure both calibration reliability and international traceability in radiation protection dosimetry. This study reports a comparative evaluation of two ionization chambers with different geometries: the PTW 32002 (spherical, 1 L) and the PTW 23361 (cylindrical, 30 cm3). Both were employed to characterize 137Cs and 60Co reference radiation fields at the CNESTEN calibration laboratory. The experimental results were compared against a theoretical benchmark provided by Monte Carlo simulations using the MCNP6.1 code to perform a comparative study with the measured values. The aim was to verify the installation’s compliance with the inverse square law and to assess the metrological suitability of the two detectors. The results showed overall agreement between experiment and simulation, with deviations ranging from ~0.2% to 10.5%, depending on photon energy and source-to-detector distance. The spherical PTW 32002 chamber demonstrated greater stability in 60Co beams, while the cylindrical PTW 23361 exhibited better accuracy in 137Cs fields. These findings highlight the importance of chamber selection with respect to photon energy and dose rate, and confirm the compliance of the CNESTEN facility with international standards, thereby supporting reduced uncertainties and improved metrological traceability in calibration services.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cobalt RadioisotopesCesium RadioisotopesRadiometryGamma RaysRadiation ProtectionMonte Carlo MethodCalibrationReproducibility of ResultsRadiation DosageHumansEquipment Design

Substanzen

Cobalt RadioisotopesCesium RadioisotopesCobalt-60Cesium-137

Autor:innen und Institutionen

  • National Center for Energy Sciences and Nuclear Technology, CNESTEN, P.O. Box 1382, R.P. 10001, Rabat, Morocco.
  • Faculty of Sciences, Ibn Tofail University, P.O. Box 133, University Avenue, 14000, Kenitra, Morocco.
  • Faculty of Economic and Management, Ibn Tofail University, P.O. Box 133, University Avenue, 14000, Kenitra, Morocco.
  • Higher Institute of Health Sciences (ISSS), Hassan First University, P.O. Box 555, Casablanca Road, 26000, Settat, Morocco.

ORCID-Profile: Taibi Zidouz

Zitieren

APA

Zidouz, T., Mouhssine, A., Tamiss, H., Didi, A., Talbi, A., Nabaoui, K., Alibrahmi, E., Chakir, E. M., Badague, A., & Zaryah, M. (2026). Comparative assessment of spherical and cylindrical ionization chambers (PTW 32002 and PTW 23361) in 60Co and 137Cs reference beams: experimental and Monte Carlo evaluation for installation compliance in gamma irradiator. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncag014

Vancouver

Zidouz T, Mouhssine A, Tamiss H, Didi A, Talbi A, Nabaoui K, et al. Comparative assessment of spherical and cylindrical ionization chambers (PTW 32002 and PTW 23361) in 60Co and 137Cs reference beams: experimental and Monte Carlo evaluation for installation compliance in gamma irradiator. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncag014

BibTeX
@article{Zidouz2026,
  author = {Zidouz, Taibi and Mouhssine, Asmaa and Tamiss, Hasbiya and Didi, Abdessamad and Talbi, Abdellatif and Nabaoui, Khalid and Alibrahmi, Elmehdi and Chakir, El Mahjoub and Badague, Abdelwahab and Zaryah, Mohamed},
  title = {Comparative assessment of spherical and cylindrical ionization chambers (PTW 32002 and PTW 23361) in 60Co and 137Cs reference beams: experimental and Monte Carlo evaluation for installation compliance in gamma irradiator},
  journal = {Radiation Protection Dosimetry},
  year = {2026},
  doi = {10.1093/rpd/ncag014}
}
Kostenlos starten →