EUVIMEDEUVIMED entdecken
Crossref

Enhancing quality assurance in external radiation therapy: A study on the use of EPID ASi1200 and ArcCHECK® phantom in VMAT plans

M Chenhaji, M El Kafhali, M Tahmasbi, D Benchekroun, I Bouadel, F Z Erradi

Radiography · 2025

DOI: 10.1016/j.radi.2025.103191 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiography, 2025. Verfasst von M Chenhaji und 5 weiteren Autor:innen. Beteiligte Einrichtung: Hassan II University of Casablanca, Faculty of Sciences Ain Chock, Casablanca, Morocco. Electronic address: meriem.chenhaji21@gmail.com. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Phantoms, Imaging, Radiotherapy Planning, Computer-Assisted, Quality Assurance, Health Care. Die Arbeit nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Volumetric modulated arc therapy (VMAT) offers precise dose delivery through dynamic modulation. However, its complexity necessitates robust quality assurance (QA) procedures. This study evaluated the Electronic Portal Imaging Device (EPID) ASi1200 and ArcCHECK® phantom in verifying VMAT plans for multiple anatomical sites. METHODS: A total of 73 VMAT treatment plans (brain, abdomen, thorax, pelvis, and head and neck) generated in the Eclipse treatment planning system (TPS) and delivered via the TrueBeam STx linear accelerator were evaluated. The calculated doses were verified using both EPID ASi1200 and ArcCHECK® systems. Gamma index analysis was performed with a 3 %/3 mm criterion and a 10 % threshold. Statistical analyses, including paired t-tests, normality testing, and Spearman correlations, were conducted to compare the agreement between the two systems across anatomical sites. RESULTS: Both verification tools achieved high Gamma pass rates (>99 %). EPID showed significantly higher agreement in pelvic plans (p < 0.001), while differences in other sites were statistically non-significant or clinically negligible (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy, Intensity-ModulatedPhantoms, ImagingRadiotherapy Planning, Computer-AssistedQuality Assurance, Health CareNeoplasmsHumansRadiotherapy Dosage

Stichwörter der Autor:innen

ArcCHECK®EPIDPortal dosimetryPre-treatment verificationQuality assuranceVMAT

Autor:innen und Institutionen

  • Hassan II University of Casablanca, Faculty of Sciences Ain Chock, Casablanca, Morocco. Electronic address: meriem.chenhaji21@gmail.com.
  • Physical Sciences and Engineering, Innovative Research and Applied Physics (IRAP) Faculty of Sciences, Moulay Ismail University, Meknes, Morocco. Electronic address: m.elkafhali@edu.umi.ac.ma.
  • Department of Radiologic Technology, School of Allied Medical Sciences, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. Electronic address: marziyeh_tahmasbi@yahoo.com.
  • Hassan II University of Casablanca, Faculty of Sciences Ain Chock, Casablanca, Morocco. Electronic address: driss.benchekroun@cern.ch.
  • LPHE - Modeling and Simulations Faculty of Science, Mohammed V University in Rabat, Rabat, Morocco. Electronic address: ikbal_bouadel@um5.ac.ma.
  • Department of Radiotherapy International Center of Oncology, Oasis-Casablanca, Morocco. Electronic address: Fatimazohra.ERRADI@gmail.com.

Zitieren

APA

Chenhaji, M., El Kafhali, M., Tahmasbi, M., Benchekroun, D., Bouadel, I., & Erradi, F. Z. (2025). Enhancing quality assurance in external radiation therapy: A study on the use of EPID ASi1200 and ArcCHECK® phantom in VMAT plans. Radiography. https://doi.org/10.1016/j.radi.2025.103191

Vancouver

Chenhaji M, El Kafhali M, Tahmasbi M, Benchekroun D, Bouadel I, Erradi FZ. Enhancing quality assurance in external radiation therapy: A study on the use of EPID ASi1200 and ArcCHECK® phantom in VMAT plans. Radiography. 2025. doi:10.1016/j.radi.2025.103191

BibTeX
@article{Chenhaji2025,
  author = {Chenhaji, M and El Kafhali, M and Tahmasbi, M and Benchekroun, D and Bouadel, I and Erradi, F Z},
  title = {Enhancing quality assurance in external radiation therapy: A study on the use of EPID ASi1200 and ArcCHECK® phantom in VMAT plans},
  journal = {Radiography},
  year = {2025},
  doi = {10.1016/j.radi.2025.103191}
}
Kostenlos starten →