EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Log file‐based quality assurance method for respiratory gating system

Wonjoong Cheon iD, Young Kyu Lee, Yunji Seol, Chan-Beom Park, Hong Qi Tan, Kyu Hye Choi, Young-Nam Kang, Byung Ock Choi

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70101 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Wonjoong Cheon und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Quality Assurance, Health Care, Phantoms, Imaging, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Fund of Seoul St.Mary's Hospital, The Catholic University of Korea, Korea Electrotechnology Research Institute, National Research Council of Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

As medical linear accelerator technology advances, enabling higher dose rate deliveries, hypofractionation regimens has increased. This necessitates respiratory gating systems that synchronize radiation delivery with tumor position, requiring simple rigorous quality assurance (QA) to ensure treatment accuracy and patient safety.

Purpose

This study aimed to propose log‐based QA for respiratory‐gated radiation therapy using the respiratory gating system and treatment machine.

Methods

4D CT scans were performed with a Varian motion phantom using a Varian Respiratory Gating for Scanner (RGSC). A treatment plan using 25%–75% respiratory phases with 100 MU was created and delivered to a solid water phantom. Treatment logs containing respiratory signals, beam on/off flags, and frame information were extracted from the treatment planning system's offline review. Log file analyses were conducted using in‐house softwares to assess temporal synchronization between respiratory phases and beam triggers. Output measurements using a calibrated ion chamber (FC65G) were performed to evaluate dosimetric accuracy. Additionally, EPID images were acquired in cine mode and analyzed frame‐by‐frame to independently verify beam delivery timing.

Results

Log file analysis revealed precise temporal synchronization, with mean time differences of 0.03 s ± 0.05 s between the planned 25% phase and beam‐on, and −0.04 s ± 0.05 s between 75% phase and beam‐off. The log‐derived beam‐on duration (2.61 s ± 0.02 s) closely matched the planned duration (2.66 s ± 0.00 s). Three‐month log data showed consistent temporal accuracy, with trigger‐on times remaining stable at 2.60 s ± 0.01 s across all measurements. Supporting ion chamber measurements confirmed dosimetric agreement between gating and non‐gating modes (difference: 0.05 cGy ± 0.09 cGy)

Conclusions

The proposed log file‐based QA method demonstrated high accuracy and reproducibility in assessing respiratory gating performance. This approach provides an efficient, objective method for standardizing QA procedures in respiratory‐gated radiation therapy, enhancing treatment accuracy and patient safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedQuality Assurance, Health CarePhantoms, ImagingRadiotherapy, Intensity-ModulatedRespiratory-Gated Imaging TechniquesFour-Dimensional Computed TomographyNeoplasmsImage Processing, Computer-AssistedHumansRadiotherapy DosageParticle AcceleratorsRespiration

Stichwörter der Autor:innen

Log file‐based analysisRGSC (Respiratory Gating for Scanner) systemquality assurance (QA)radiation therapyrespiratory gating

Autor:innen und Institutionen

  • Department of Radiation Oncology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
  • Department of Radiation Oncology, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Republic of Korea.
  • Department of Biomedicine & Helath Sciences, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
  • Division of Radiation Oncology, National Cancer Centre Singapore, Singapore, Singapore.
  • Oncology Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore.
  • School of Physics and Mathematical Science, Nanyang Technological University, Singapore, Singapore.

ORCID-Profile: Wonjoong Cheon

Förderung

  • Research Fund of Seoul St.Mary's Hospital, The Catholic University of Korea
  • Korea Electrotechnology Research Institute
  • National Research Council of Science and Technology

Zitieren

APA

Cheon, W., Lee, Y. K., Seol, Y., Park, C. B., Tan, H. Q., Choi, K. H., Kang, Y. N., & Choi, B. O. (2025). Log file‐based quality assurance method for respiratory gating system. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70101

Vancouver

Cheon W, Lee YK, Seol Y, Park CB, Tan HQ, Choi KH, et al. Log file‐based quality assurance method for respiratory gating system. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70101

BibTeX
@article{Cheon2025,
  author = {Cheon, Wonjoong and Lee, Young Kyu and Seol, Yunji and Park, Chan-Beom and Tan, Hong Qi and Choi, Kyu Hye and Kang, Young-Nam and Choi, Byung Ock},
  title = {Log file‐based quality assurance method for respiratory gating system},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70101}
}
Kostenlos starten →