2D CAIPI accelerated 3D multi-slab diffusion weighted EPI combined with qModeL reconstruction for fast high resolution microstructure imaging
Magnetic Resonance Imaging · 2024
DOI: 10.1016/j.mri.2024.04.003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Chu-Yu Lee und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Iowa, Iowa City, IA, United States of America. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Diffusion Magnetic Resonance Imaging, Algorithms. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIH HHS, NCRR NIH HHS.
Abstract (Originalsprache)
PURPOSE: To develop acceleration strategies for 3D multi-slab diffusion weighted imaging (3D ms-DWI) for enabling applications that require simultaneously high spatial (1 mm isotropic) and angular (> 30 directions) resolutions. METHODS: 3D ms-DWI offers high SNR-efficiency, with the ability to achieve high isotropic spatial resolution, yet suffers from long scan-times for studies requiring high angular resolutions. We develop 6D k-q space acceleration strategies to reduce the scan-time. Specifically, we develop non-uniform 3D ky-kz under-sampling employing a shot-selective 2D CAIPI sampling approach. To achieve inter-shot phase-compensation, 2D navigators were employed that utilize the same CAIPI trajectory. An iterative model-based 3D multi-shot reconstruction was designed by incorporating phase into the forward encoding process. Additionally, the shot-selective non-uniform ky-kz CAIPI acceleration was randomized along the q-dimension. The 3D model-based multi-shot reconstruction is then extended to a joint reconstruction that simultaneously reconstructs all the q-space points, with the help of a spatial total variation and deep-learned q-space regularization. RESULTS: The proposed reconstruction is shown to achieve adequate phase-compensation in both 2D CAIPI accelerated and additional ky-kz under-sampled cases. Using retrospective under-sampling experiments, we show that k-q accelerations close a factor of 12 can be achieved with a reconstruction error < 3% for both single and multi-shell data. This translates to a scan-time reduction by 3-fold for experiments with simultaneously high spatial and angular resolutions. CONCLUSION: The proposed method facilitates the utilization of 3D ms-DWI for simultaneously high k-q resolution applications with close to 3× reduced scan-time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University of Iowa, Iowa City, IA, United States of America.
- Department of Radiology, University of Iowa, Iowa City, IA, United States of America. Electronic address: merry-mani@uiowa.edu.
Förderung
- NIBIB NIH HHS
- NIH HHS
- NCRR NIH HHS
- National Institutes of Health
Zitieren
APA
Lee, C. Y., & Mani, M. (2024). 2D CAIPI accelerated 3D multi-slab diffusion weighted EPI combined with qModeL reconstruction for fast high resolution microstructure imaging. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.04.003
Vancouver
Lee CY, Mani M. 2D CAIPI accelerated 3D multi-slab diffusion weighted EPI combined with qModeL reconstruction for fast high resolution microstructure imaging. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.04.003
BibTeX
@article{Lee2024,
author = {Lee, Chu-Yu and Mani, Merry},
title = {2D CAIPI accelerated 3D multi-slab diffusion weighted EPI combined with qModeL reconstruction for fast high resolution microstructure imaging},
journal = {Magnetic Resonance Imaging},
year = {2024},
doi = {10.1016/j.mri.2024.04.003}
}
EUVIMED