Quantitative Diffusion and T2 Mapping Using RF ‐Modulated Phase‐Based Gradient Echo Imaging
Magnetic Resonance in Medicine · 2026-07 · 96 (1) · 49-65
DOI: 10.1002/mrm.70312 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 11.03.2026. Verfasst von Daiki Tamada und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Echo-Planar Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, NCATS NIH HHS, National Center for Advancing Translational Sciences.
Abstract (Originalsprache)
Purpose
To introduce and evaluate the feasibility of a novel RF‐phase modulated gradient echo (GRE) method for quantitative diffusion MRI, aimed at mitigating geometric distortion and enabling high‐resolution 3D quantitative diffusion/T2 mapping as a complementary alternative to conventional DWI. Theory and Methods The proposed phase‐based diffusion (PBD) method employs RF phase modulation to encode both diffusion and T2 information into the GRE signal phase. A closed‐form analytical model enables joint apparent diffusion coefficient (ADC) and T2 mapping via iterative reconstruction. The method's feasibility was evaluated via Bloch equation simulations, phantom experiments, and preliminary in vivo imaging studies.
Results
Monte Carlo simulations revealed that PBD provides more accurate median ADC estimates at low signal‐to‐noise ratios (SNRs) compared to conventional single‐shot echo‐planar imaging (SS‐EPI), although PBD exhibited greater variability. Phantom studies demonstrated good agreement for PBD‐derived ADC values (e.g., R 2 = 0.99) with reference methods and strong correlation for PBD‐derived T2 values (e.g., R 2 = 0.89), though the latter showed some systematic bias in phantoms. In vivo results from patients with benign or malignant prostate disease demonstrated the feasibility of the PBD method to provide high‐resolution ADC and T2 maps with minimal geometric distortions relative to conventional SS‐EPI.
Conclusion
PBD provides ADC and T2 maps with improved geometric fidelity in phantoms and in vivo, and offers robust median ADC estimates from noisy data based on simulations. This combination of spatial precision and noise characteristics makes PBD promising for applications such as high‐resolution DWI for prostate MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Urology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Carbone Cancer Center, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA.
ORCID-Profile: Daiki Tamada, Diego Hernando, Scott B Reeder
Förderung
- NCI NIH HHS
- NCATS NIH HHS
- National Center for Advancing Translational Sciences
Zitieren
APA
Tamada, D., Pirasteh, A., Jarrard, D. F., Hernando, D., & Reeder, S. B. (2026). Quantitative Diffusion and T2 Mapping Using RF ‐Modulated Phase‐Based Gradient Echo Imaging. Magnetic Resonance in Medicine, 96(1), 49-65. https://doi.org/10.1002/mrm.70312
Vancouver
Tamada D, Pirasteh A, Jarrard DF, Hernando D, Reeder SB. Quantitative Diffusion and T2 Mapping Using RF ‐Modulated Phase‐Based Gradient Echo Imaging. Magnetic Resonance in Medicine. 2026;96(1):49-65. doi:10.1002/mrm.70312
BibTeX
@article{Tamada2026,
author = {Tamada, Daiki and Pirasteh, Ali and Jarrard, David F and Hernando, Diego and Reeder, Scott B},
title = {Quantitative Diffusion and T2 Mapping Using RF ‐Modulated Phase‐Based Gradient Echo Imaging},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {1},
pages = {49--65},
doi = {10.1002/mrm.70312}
}
EUVIMED