Single‐shot echo planar time‐resolved imaging for multi‐echo functional MRI and distortion‐free diffusion imaging
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30327 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Zijing Dong und 3 weiteren Autor:innen. Beteiligte Einrichtung: Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA. Hauptthemen laut MEDLINE: Echo-Planar Imaging, Signal-To-Noise Ratio, Image Processing, Computer-Assisted, Brain. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 102 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NINDS NIH HHS, NIA NIH HHS, NIBIB NIH HHS.
Abstract (Originalsprache)
Purpose
To develop a single‐shot SNR‐efficient distortion‐free multi‐echo imaging technique for dynamic imaging applications.
Methods
Echo planar time‐resolved imaging (EPTI) was first introduced as a multi‐shot technique for distortion‐free multi‐echo imaging. This work aims to develop single‐shot EPTI (ss‐EPTI) to achieve improved robustness to motion/physiological noise, increased temporal resolution, and higher SNR efficiency. A new spatiotemporal encoding that enables reduced phase‐encoding blips and minimized echo spacing under the single‐shot regime was developed, which improves sampling efficiency and enhances spatiotemporal correlation in the k‐TE space for improved reconstruction. A continuous readout with minimized deadtime was employed to optimize SNR efficiency. Moreover, k‐TE partial Fourier and simultaneous multi‐slice acquisition were integrated for further acceleration. Results ss‐EPTI provided distortion‐free imaging with densely sampled multi‐echo images at standard resolutions (e.g., ˜1.25 to 3 mm) in a single‐shot. Improved SNR efficiency was observed in ss‐EPTI due to improved motion/physiological‐noise robustness and efficient continuous readout. Its ability to eliminate dynamic distortions—geometric changes across dynamics due to field changes induced by physiological variations or eddy currents—further improved the data's temporal stability. For multi‐echo fMRI, ss‐EPTI's multi‐echo images recovered signal dropout in short‐ regions and provided TE‐dependent functional information to distinguish non‐BOLD noise for further tSNR improvement. For diffusion MRI, it achieved shortened TEs for improved SNR and provided images free from both B 0 ‐induced and diffusion‐encoding‐dependent eddy‐current‐induced distortions with multi‐TE diffusion metrics. Conclusion ss‐EPTI provides SNR‐efficient distortion‐free multi‐echo imaging with comparable temporal resolutions to ss‐EPI, offering a new acquisition tool for dynamic imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA.
- Harvard-MIT Health Sciences and Technology, MIT, Cambridge, Massachusetts, USA.
ORCID-Profile: Zijing Dong, Fuyixue Wang
Förderung
- NINDS NIH HHS
- NIA NIH HHS
- NIBIB NIH HHS
- NIH HHS
- National Institute on Aging
- National Institute of Biomedical Imaging and Bioengineering
- NIH Office of the Director
- National Institute of Neurological Disorders and Stroke
Zitieren
APA
Dong, Z., Wald, L. L., Polimeni, J. R., & Wang, F. (2025). Single‐shot echo planar time‐resolved imaging for multi‐echo functional MRI and distortion‐free diffusion imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30327
Vancouver
Dong Z, Wald LL, Polimeni JR, Wang F. Single‐shot echo planar time‐resolved imaging for multi‐echo functional MRI and distortion‐free diffusion imaging. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30327
BibTeX
@article{Dong2025,
author = {Dong, Zijing and Wald, Lawrence L and Polimeni, Jonathan R and Wang, Fuyixue},
title = {Single‐shot echo planar time‐resolved imaging for multi‐echo functional MRI and distortion‐free diffusion imaging},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30327}
}
EUVIMED