Evaluation of output factors of different radiotherapy planning systems using Exradin W2 plastic scintillator detector

Yasuharu Ando, Masahiro Okada, Natsuko Matsumoto, Kawasaki Ikuhiro, Soichiro Ishihara, Hiroshi Kiriu, Yoshinori Tanabe

Physical and Engineering Sciences in Medicine · 2024

DOI: 10.1007/s13246-024-01438-5 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Physical and Engineering Sciences in Medicine, 2024. Verfasst von Yasuharu Ando und 6 weiteren Autor:innen. Beteiligte Einrichtung: Hiroshima City Hospital, Hiroshima, Japan. Hauptthemen laut MEDLINE: Plastics, Scintillation Counting, Radiotherapy Planning, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aims to evaluate the output factors (OPF) of different radiation therapy planning systems (TPSs) using a plastic scintillator detector (PSD). The validation results for determining a practical field size for clinical use were verified. The implemented validation system was an Exradin W2 PSD. The focus was to validate the OPFs of the small irradiation fields of two modeled radiation TPSs using RayStation version 10.0.1 and Monaco version 5.51.10. The linear accelerator used for irradiation was a TrueBeam with three energies: 4, 6, and 10 MV. RayStation calculations showed that when the irradiation field size was reduced from 10 × 10 to 0.5 × 0.5 cm2, the results were within 2.0% of the measured values for all energies. Similarly, the values calculated using Monaco were within approximately 2.0% of the measured values for irradiation field sizes between 10 × 10 and 1.5 × 1.5 cm2 for all beam energies of interest. Thus, PSDs are effective validation tools for OPF calculations in TPS. A TPS modeled with the same source data has different minimum irradiation field sizes that can be calculated. These findings could aid in verification of equipment accuracy for treatment planning requiring highly accurate dose calculations and for third-party evaluation of OPF calculations for TPS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PlasticsScintillation CountingRadiotherapy Planning, Computer-AssistedRadiotherapy DosageHumansParticle AcceleratorsReproducibility of Results

Stichwörter der Autor:innen

Output factorPlastic scintillatorRadiation therapySmall irradiation field

Substanzen

Plastics

Autor:innen und Institutionen

  • Hiroshima City Hospital, Hiroshima, Japan.
  • Hiroshima City North Medical Center Asa Citizens Hospital, Hiroshima, Japan.
  • Department of Radiological Technology, Graduate School of Health Sciences, Okayama University, 5-1 Shikata-cho, 2-chome, Kita-ku, Okayama, 700-8558, Japan. tanabey@okayama-u.ac.jp.

Zitieren

APA

Ando, Y., Okada, M., Matsumoto, N., Ikuhiro, K., Ishihara, S., Kiriu, H., & Tanabe, Y. (2024). Evaluation of output factors of different radiotherapy planning systems using Exradin W2 plastic scintillator detector. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-024-01438-5

Vancouver

Ando Y, Okada M, Matsumoto N, Ikuhiro K, Ishihara S, Kiriu H, et al. Evaluation of output factors of different radiotherapy planning systems using Exradin W2 plastic scintillator detector. Physical and Engineering Sciences in Medicine. 2024. doi:10.1007/s13246-024-01438-5

BibTeX
@article{Ando2024,
  author = {Ando, Yasuharu and Okada, Masahiro and Matsumoto, Natsuko and Ikuhiro, Kawasaki and Ishihara, Soichiro and Kiriu, Hiroshi and Tanabe, Yoshinori},
  title = {Evaluation of output factors of different radiotherapy planning systems using Exradin W2 plastic scintillator detector},
  journal = {Physical and Engineering Sciences in Medicine},
  year = {2024},
  doi = {10.1007/s13246-024-01438-5}
}
Kostenlos starten →