EUVIMEDEUVIMED entdecken
Crossref

Impact of iso-dose levels on pre-treatment quality assurance in volumetric modulated arc therapy

Sumanta Manna, Sanjib Gayen, Sonal Varshney

Radiological Physics and Technology · 2025

DOI: 10.1007/s12194-025-00902-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiological Physics and Technology, 2025. Verfasst von Sumanta Manna und 2 weiteren Autor:innen. Beteiligte Einrichtung: Specialty of Medical Physics, Kalyan Singh Super Specialty Cancer Institute, C G City, Lucknow, Uttar Pradesh, 226002, India. Sumanta7915@gmail.con. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Quality Assurance, Health Care, Radiation Dosage. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The current standard of modern radiotherapy pre-treatment evaluation of dose distributions measured using gamma pass percentage is the predominant metric for Patient-Specific Quality Assurance (PSQA). The aim of the study was to analyze the impact of the different dose levels for three different gamma criteria in various anatomical sites. Retrospectively selected 120 VMAT plans of the brain, head and neck, thorax, and pelvic sites were considered for this study. Quality assurance plans were created and measurements were done using PTW Octavius 4D phantom. Three different gamma criteria were used to evaluate different dose levels' volume gamma passing rates. The maximum gamma passing rate for all dose levels except 100% with a 3%/3 mm criterion was observed for the pelvis site. A significant variation in dose levels was observed with the 3%/2 mm gamma criteria for head and neck sites, particularly above the 85% dose level compared to other anatomical sites. Using 2%/2 mm gamma criteria, there was a rapid fall in the gamma passing rate and all the dose levels showed a significant variation among different sites. This study demonstrated significant variations in gamma passing rates across anatomical sites and dose levels, emphasizing the importance of tailored QA protocols. The findings underscore the need for site-specific action limits and highlight the sensitivity of stricter gamma criteria for detecting errors in complex treatment plans.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy, Intensity-ModulatedQuality Assurance, Health CareRadiation DosageRadiotherapy DosageHumansRadiotherapy Planning, Computer-AssistedPhantoms, ImagingRetrospective Studies

Stichwörter der Autor:innen

Dose levelGamma indexOctavius4DQuality assuranceRadiotherapyVMAT

Autor:innen und Institutionen

  • Specialty of Medical Physics, Kalyan Singh Super Specialty Cancer Institute, C G City, Lucknow, Uttar Pradesh, 226002, India. Sumanta7915@gmail.con.
  • Department of Medical Physics, Apollo Proton Cancer Centre, Chennai, Tamil Nadu, 600041, India. physanjib@gmail.com.
  • Department of Radiation Oncology, All India Institute of Medical Sciences, Jodhpur, Rajasthan, 342005, India.

Zitieren

APA

Manna, S., Gayen, S., & Varshney, S. (2025). Impact of iso-dose levels on pre-treatment quality assurance in volumetric modulated arc therapy. Radiological Physics and Technology. https://doi.org/10.1007/s12194-025-00902-5

Vancouver

Manna S, Gayen S, Varshney S. Impact of iso-dose levels on pre-treatment quality assurance in volumetric modulated arc therapy. Radiological Physics and Technology. 2025. doi:10.1007/s12194-025-00902-5

BibTeX
@article{Manna2025,
  author = {Manna, Sumanta and Gayen, Sanjib and Varshney, Sonal},
  title = {Impact of iso-dose levels on pre-treatment quality assurance in volumetric modulated arc therapy},
  journal = {Radiological Physics and Technology},
  year = {2025},
  doi = {10.1007/s12194-025-00902-5}
}
Kostenlos starten →