Quantification of the rotating frame relaxation time T 2ρ : Comparison of balanced spin‐lock and continuous‐wave Malcolm‐Levitt preparations
NMR in Biomedicine · 2024
DOI: 10.1002/nbm.5199 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Maximilian Gram und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany. Hauptthemen laut MEDLINE: Phantoms, Imaging, Magnetic Resonance Imaging. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry of Education and Research, German Research Council, Marija Orlovic Foundation: Young Investigator Fund for Innovative Cardiology.
Abstract (Originalsprache)
For the quantification of rotating frame relaxation times, the T 2ρ relaxation pathway plays an essential role. Nevertheless, T 2ρ imaging has been studied only to a small extent compared with T 1ρ , and preparation techniques for T 2ρ have so far been adapted from T 1ρ methods. In this work, two different preparation concepts are compared specifically for the use of T 2ρ mapping. The first approach involves transferring the balanced spin‐locking (B‐SL) concept of T 1ρ imaging. The second and newly proposed approach is a continuous‐wave Malcolm‐Levitt (CW‐MLEV) pulse train with zero echo times and was motivated from T 2 preparation strategies. The modules are tested in Bloch simulations for their intrinsic sensitivity to field inhomogeneities and validated in phantom experiments. In addition, myocardial T 2ρ mapping was performed in mice as an exemplary application. Our results demonstrate that the CW‐MLEV approach provides superior robustness and thus suggest that established methods of T 1ρ imaging are not best suited for T 2ρ experiments. In the presence of field inhomogeneities, the simulations indicated an increased banding compensation by a factor of 4.1 compared with B‐SL. Quantification of left ventricular T 2ρ time in mice yielded more consistent results, and values in the range of 59.2–61.1 ms (R 2 = 0.986–0.992) were observed at 7 T.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany.
- Experimental Physics 5, University of Würzburg, Würzburg, Germany.
- Comprehensive Heart Failure Center (CHFC), University Hospital Würzburg, Würzburg, Germany.
- Department of Cardiovascular Genetics, Comprehensive Heart Failure Center (CHFC), University Hospital Würzburg, Würzburg, Germany.
ORCID-Profile: Maximilian Gram
Förderung
- Federal Ministry of Education and Research
- German Research Council
- Marija Orlovic Foundation: Young Investigator Fund for Innovative Cardiology
- Bundesministerium für Bildung und Forschung
Zitieren
APA
Gram, M., Christa, M., Gutjahr, F. T., Albertova, P., Williams, T., Jakob, P. M., Bauer, W. R., & Nordbeck, P. (2024). Quantification of the rotating frame relaxation time T 2ρ : Comparison of balanced spin‐lock and continuous‐wave Malcolm‐Levitt preparations. NMR in Biomedicine. https://doi.org/10.1002/nbm.5199
Vancouver
Gram M, Christa M, Gutjahr FT, Albertova P, Williams T, Jakob PM, et al. Quantification of the rotating frame relaxation time T 2ρ : Comparison of balanced spin‐lock and continuous‐wave Malcolm‐Levitt preparations. NMR in Biomedicine. 2024. doi:10.1002/nbm.5199
BibTeX
@article{Gram2024,
author = {Gram, Maximilian and Christa, Martin and Gutjahr, Fabian Tobias and Albertova, Petra and Williams, Tatjana and Jakob, Peter Michael and Bauer, Wolfgang Rudolf and Nordbeck, Peter},
title = {Quantification of the rotating frame relaxation time T 2ρ : Comparison of balanced spin‐lock and continuous‐wave Malcolm‐Levitt preparations},
journal = {NMR in Biomedicine},
year = {2024},
doi = {10.1002/nbm.5199}
}
EUVIMED