EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Quantification of the rotating frame relaxation time T 2ρ : Comparison of balanced spin‐lock and continuous‐wave Malcolm‐Levitt preparations

Maximilian Gram iD, Martin Christa, Fabian Tobias Gutjahr, Petra Albertova, Tatjana Williams, Peter Michael Jakob, Wolfgang Rudolf Bauer, Peter Nordbeck

NMR in Biomedicine · 2024

DOI: 10.1002/nbm.5199 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Maximilian Gram und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany. Hauptthemen laut MEDLINE: Phantoms, Imaging, Magnetic Resonance Imaging. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry of Education and Research, German Research Council, Marija Orlovic Foundation: Young Investigator Fund for Innovative Cardiology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

For the quantification of rotating frame relaxation times, the T 2ρ relaxation pathway plays an essential role. Nevertheless, T 2ρ imaging has been studied only to a small extent compared with T 1ρ , and preparation techniques for T 2ρ have so far been adapted from T 1ρ methods. In this work, two different preparation concepts are compared specifically for the use of T 2ρ mapping. The first approach involves transferring the balanced spin‐locking (B‐SL) concept of T 1ρ imaging. The second and newly proposed approach is a continuous‐wave Malcolm‐Levitt (CW‐MLEV) pulse train with zero echo times and was motivated from T 2 preparation strategies. The modules are tested in Bloch simulations for their intrinsic sensitivity to field inhomogeneities and validated in phantom experiments. In addition, myocardial T 2ρ mapping was performed in mice as an exemplary application. Our results demonstrate that the CW‐MLEV approach provides superior robustness and thus suggest that established methods of T 1ρ imaging are not best suited for T 2ρ experiments. In the presence of field inhomogeneities, the simulations indicated an increased banding compensation by a factor of 4.1 compared with B‐SL. Quantification of left ventricular T 2ρ time in mice yielded more consistent results, and values in the range of 59.2–61.1 ms (R 2 = 0.986–0.992) were observed at 7 T.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingMagnetic Resonance ImagingAnimalsSpin LabelsMiceRotationAlgorithmsReproducibility of ResultsComputer SimulationMice, Inbred C57BL

Stichwörter der Autor:innen

MLEVT1ρT2ρcMRImicespin‐lock

Substanzen

Spin Labels

Autor:innen und Institutionen

  • Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany.
  • Experimental Physics 5, University of Würzburg, Würzburg, Germany.
  • Comprehensive Heart Failure Center (CHFC), University Hospital Würzburg, Würzburg, Germany.
  • Department of Cardiovascular Genetics, Comprehensive Heart Failure Center (CHFC), University Hospital Würzburg, Würzburg, Germany.

ORCID-Profile: Maximilian Gram

Förderung

  • Federal Ministry of Education and Research
  • German Research Council
  • Marija Orlovic Foundation: Young Investigator Fund for Innovative Cardiology
  • Bundesministerium für Bildung und Forschung

Zitieren

APA

Gram, M., Christa, M., Gutjahr, F. T., Albertova, P., Williams, T., Jakob, P. M., Bauer, W. R., & Nordbeck, P. (2024). Quantification of the rotating frame relaxation time T 2ρ : Comparison of balanced spin‐lock and continuous‐wave Malcolm‐Levitt preparations. NMR in Biomedicine. https://doi.org/10.1002/nbm.5199

Vancouver

Gram M, Christa M, Gutjahr FT, Albertova P, Williams T, Jakob PM, et al. Quantification of the rotating frame relaxation time T 2ρ : Comparison of balanced spin‐lock and continuous‐wave Malcolm‐Levitt preparations. NMR in Biomedicine. 2024. doi:10.1002/nbm.5199

BibTeX
@article{Gram2024,
  author = {Gram, Maximilian and Christa, Martin and Gutjahr, Fabian Tobias and Albertova, Petra and Williams, Tatjana and Jakob, Peter Michael and Bauer, Wolfgang Rudolf and Nordbeck, Peter},
  title = {Quantification of the rotating frame relaxation time T 2ρ : Comparison of balanced spin‐lock and continuous‐wave Malcolm‐Levitt preparations},
  journal = {NMR in Biomedicine},
  year = {2024},
  doi = {10.1002/nbm.5199}
}
Kostenlos starten →