Effective Modeling of Continuous Wave Z‐Spectra for Quantitative CEST and CESL MRI Across Exchange Regimes
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70483 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Chris Lippe und 1 weiteren Autor:innen. Beteiligte Einrichtung: Multiscale Imaging Centre, Clinic of Radiology, University of Münster, Münster, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Purpose
Chemical exchange saturation transfer (CEST) and chemical exchange‐sensitive spin‐lock (CESL) MRI enable spectroscopic imaging with high sensitivity, but conventional analysis methods often fail as exchange approaches the fast‐exchange limit. We introduce the AB‐MT+n model for robust, reproducible quantification of continuous‐wave ‐spectra across exchange regimes. Theory and Methods The AB‐MT+n model describes continuous‐wave ‐spectra by a five‐parameter basis for direct water saturation, semi‐solid magnetization transfer, and fast exchange, which can be extended by off‐resonant components for separable slow‐ and intermediate‐exchanging pools. Performance was evaluated in simulations, phantoms, and in vivo glucose‐enhanced CESL (glucoCESL) of a mouse brain.
Results
Simulations showed that AB‐MT+n recovers the maximally accessible information from ‐spectra with minimal parameterization, with lower model orders sufficing for faster exchange. In phantoms, the slower‐exchanging glutamate pool was quantified reliably by Lorentzian analysis (), whereas fast‐exchanging glucose was not captured accurately by Lorentzian, MTR, or the full analytical model under varying glutamate concentration (). In contrast, the pool‐unspecific asymmetry parameter preserved strong linearity with glucose concentration (). Reduced model orders also sufficed in seven‐pool gray matter simulations and enabled robust quantification of in vivo glucoCESL data.
Conclusion
AB‐MT+n provides an accurate, acquisition‐independent, modular description of continuous‐wave ‐spectra and improves quantification, particularly in the fast‐exchange regime.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Multiscale Imaging Centre, Clinic of Radiology, University of Münster, Münster, Germany.
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Bonn, Germany.
ORCID-Profile: Chris Lippe, Verena Hoerr
Förderung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Lippe, C., & Hoerr, V. (2026). Effective Modeling of Continuous Wave Z‐Spectra for Quantitative CEST and CESL MRI Across Exchange Regimes. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70483
Vancouver
Lippe C, Hoerr V. Effective Modeling of Continuous Wave Z‐Spectra for Quantitative CEST and CESL MRI Across Exchange Regimes. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70483
BibTeX
@article{Lippe2026,
author = {Lippe, Chris and Hoerr, Verena},
title = {Effective Modeling of Continuous Wave Z‐Spectra for Quantitative CEST and CESL MRI Across Exchange Regimes},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70483}
}
EUVIMED