EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Boosting the velocity detection limit of 3D single‐cell tracking time‐lapse MRI by balanced SSFP imaging

Enrica Wilken iD, Asli Havlas iD, Lydia Wachsmuth, Max Masthoff, Clemens Diwoky, Cornelius Faber iD

Magnetic Resonance in Medicine · 2025-09 · 94 (3) · 1152-1165

DOI: 10.1002/mrm.30553 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 23.05.2025. Verfasst von Enrica Wilken und 5 weiteren Autor:innen. Beteiligte Einrichtung: Clinic of Radiology, University of Münster, Münster, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Imaging, Three-Dimensional, Cell Tracking, Brain. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Time‐lapse MRI allows for the dynamic tracking of single iron‐labeled cells. However, the time required for spatial encoding creates a temporal blur and, therefore, a limited ability to resolve moving cells. To study fast moving cells, such as rolling immune cells along the endothelium during inflammatory processes, advanced accelerated acquisition techniques are required.

Methods

Balanced SSFP (bSSFP) imaging is applied to phantom and in vivo murine brain time‐lapse MRI measurements at 9.4 T. Its detection capability of moving iron‐labeled cells is compared with conventional gradient echo imaging (GRE) for 2D Cartesian sampling and evaluated for fully sampled and accelerated reconstructions with compressed sensing for 3D interleaved radial sampling in bSSFP.

Results

Both phantom and in vivo time‐lapse MRI measurements show that single cells can be followed dynamically using bSSFP. High temporal resolution of less than 2 min reduces geometric distortion. The velocity detection limit increases to 0.8 mm/min in vitro and previously hidden fast‐moving cells are recovered. Interleaved 3D radial sampling enables 3D cell tracking and simultaneous imaging at varying acceleration factors. Fivefold acceleration with compressed sensing optimizes cell visibility, image quality, and temporal resolution. Conclusion bSSFP time‐lapse MRI improves single‐cell tracking by enhancing temporal resolution. In vitro, the velocity detection limit is increased fourfold compared to conventional GRE. Interleaved 3D radial bSSFP offers whole‐brain coverage at isotropic spatial resolution and retrospective reconstruction of both fully sampled and high temporal resolution images.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingImaging, Three-DimensionalCell TrackingBrainTime-Lapse ImagingSingle-Cell AnalysisAnimalsMicePhantoms, ImagingAlgorithmsImage EnhancementReproducibility of ResultsSensitivity and Specificity

Stichwörter der Autor:innen

bSSFPcompressed sensinghigh temporal resolutionradial samplingsingle‐cell trackingtime‐lapse MRI

Autor:innen und Institutionen

  • Clinic of Radiology, University of Münster, Münster, Germany.
  • Institute of Molecular Biosciences, University of Graz, Graz, Austria.

ORCID-Profile: Enrica Wilken, Asli Havlas, Cornelius Faber

Förderung

  • Deutsche Forschungsgemeinschaft

Zitieren

APA

Wilken, E., Havlas, A., Wachsmuth, L., Masthoff, M., Diwoky, C., & Faber, C. (2025). Boosting the velocity detection limit of 3D single‐cell tracking time‐lapse MRI by balanced SSFP imaging. Magnetic Resonance in Medicine, 94(3), 1152-1165. https://doi.org/10.1002/mrm.30553

Vancouver

Wilken E, Havlas A, Wachsmuth L, Masthoff M, Diwoky C, Faber C. Boosting the velocity detection limit of 3D single‐cell tracking time‐lapse MRI by balanced SSFP imaging. Magnetic Resonance in Medicine. 2025;94(3):1152-1165. doi:10.1002/mrm.30553

BibTeX
@article{Wilken2025,
  author = {Wilken, Enrica and Havlas, Asli and Wachsmuth, Lydia and Masthoff, Max and Diwoky, Clemens and Faber, Cornelius},
  title = {Boosting the velocity detection limit of 3D single‐cell tracking time‐lapse MRI by balanced SSFP imaging},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  volume = {94},
  number = {3},
  pages = {1152--1165},
  doi = {10.1002/mrm.30553}
}