Cross‐Platform Demonstration of an Autonomous MRI Field Camera

Oskar Björkqvist iD, Klaas P Pruessmann iD

Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 464-471

DOI: 10.1002/mrm.70601 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 02.10.2026. Verfasst von Oskar Björkqvist und 1 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Enhancement. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swiss National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Recent work has proposed self‐synchronization, self‐calibration, and means of sequence parsing to enhance the versatility of field cameras. The purpose of this paper is to expand this approach to more complex sequences and verify feasibility across distinct scanner platforms.

Methods

A field camera was formed from six field probes in a rigid‐body arrangement and deployed in two commercial MRI scanners. Epoch folding for synchronization and the formation of sequence diagrams were expanded to nested sequences. Autonomous camera operation was used to record advanced sequences involving gradient‐echo trains, spin‐echo trains, and diffusion‐tensor encoding.

Results

Autonomous camera operation was successful in both scanners, yielding sequence diagrams for all sequences explored.

Conclusion

Autonomy of field cameras permits use across different MRI systems and degrees of sequence complexity. Potential applications range from method development and validation to sequence harmonization, multi‐center studies, and quality assurance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingImage EnhancementEquipment DesignEquipment Failure AnalysisReproducibility of ResultsSensitivity and SpecificityAutonomous Robots

Stichwörter der Autor:innen

autonomyfield camerasquality assurancesequence detectionsequence development

Autor:innen und Institutionen

  • Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland.

ORCID-Profile: Oskar Björkqvist, Klaas P Pruessmann

Förderung

  • Swiss National Science Foundation

Zitieren

APA

Björkqvist, O., & Pruessmann, K. P. (2027). Cross‐Platform Demonstration of an Autonomous MRI Field Camera. Magnetic Resonance in Medicine, 97(1), 464-471. https://doi.org/10.1002/mrm.70601

Vancouver

Björkqvist O, Pruessmann KP. Cross‐Platform Demonstration of an Autonomous MRI Field Camera. Magnetic Resonance in Medicine. 2027;97(1):464-471. doi:10.1002/mrm.70601

BibTeX
@article{Bjrkqvist2027,
  author = {Björkqvist, Oskar and Pruessmann, Klaas P},
  title = {Cross‐Platform Demonstration of an Autonomous MRI Field Camera},
  journal = {Magnetic Resonance in Medicine},
  year = {2027},
  volume = {97},
  number = {1},
  pages = {464--471},
  doi = {10.1002/mrm.70601}
}
Kostenlos starten →