Imaging the Internal Auditory Canal with an 8 × 2 Transceiver Array Head Coil at 7T
American Journal of Neuroradiology · 2025
DOI: 10.3174/ajnr.a8569 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Neuroradiology, 2025. Verfasst von A Nada und 8 weiteren Autor:innen. Beteiligte Einrichtung: From the Washington University in St. Louis (A.N.), School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, Missouri anada@wustl.edu. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Ear, Inner, Image Enhancement. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, Common Fund.
Abstract (Originalsprache)
7T neuroimaging has known problems with B1 + strength, homogeneity and B0 susceptibility that make imaging in the inferior brain regions difficult. We investigated the utility of a decoupled 8 × 2 transceiver coil and shim insert to image the internal auditory canal (IAC) and inferior brain in comparison to the standard Nova 8/32 coil. B1 +, B0, and the T2 sampling perfection with application-optimized contrasts by using flip angle evolution sequence (SPACE) were compared by using research and standard methods in n = 8 healthy adults by using a Terra system. A T2 TSE was also acquired, and 2 neuroradiologists evaluated structures in and around the IAC, blinded to the acquisition, by using a 5-point Likert scale. The Nova 8/32 coil gave lower B1 + inferiorly compared with the whole brain while the transceiver maintained similar B1 + throughout. SPACE images showed that the transceiver performed significantly better, e.g., the transceiver scored 4.0 ± 0.8 in the left IAC, compared with 2.5 ± 0.8 with the Nova 8/32. With T2-weighted imaging that places a premium on refocusing pulses, these results show that with improved B1 + performance inferiorly, good visualization of the structure of the IAC and inferior brain regions is possible at 7T.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- From the Washington University in St. Louis (A.N.), School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, Missouri anada@wustl.edu.
- Department of Radiology (J.P.C., J.J., C.M., J.H.K., J.W.P.), University of Missouri, Columbia, Missouri.
- Department of Otolaryngology (A.R.), University of Missouri, Columbia, Missouri.
- Department of Neurosurgery (S.B.C.), University of Missouri, Columbia, Missouri.
- Resonance Research Inc. (H.P.H.), Billerica, Massachusetts.
Förderung
- NIBIB NIH HHS
- Common Fund
Zitieren
APA
Nada, A., Cousins, J. P., Rivera, A., Carr, S. B., Jones, J., Minor, C., Hetherington, H. P., Kim, J. H., & Pan, J. W. (2025). Imaging the Internal Auditory Canal with an 8 × 2 Transceiver Array Head Coil at 7T. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a8569
Vancouver
Nada A, Cousins JP, Rivera A, Carr SB, Jones J, Minor C, et al. Imaging the Internal Auditory Canal with an 8 × 2 Transceiver Array Head Coil at 7T. American Journal of Neuroradiology. 2025. doi:10.3174/ajnr.a8569
BibTeX
@article{Nada2025,
author = {Nada, A and Cousins, J P and Rivera, A and Carr, S B and Jones, J and Minor, C and Hetherington, H P and Kim, J H and Pan, J W},
title = {Imaging the Internal Auditory Canal with an 8 × 2 Transceiver Array Head Coil at 7T},
journal = {American Journal of Neuroradiology},
year = {2025},
doi = {10.3174/ajnr.a8569}
}