Spatiotemporal Encoding With Nonlinear Gradient Hardware Using Pulseq: From Principles to Practical Demonstration
Magnetic Resonance in Medicine · 2026-06 · 95 (6) · 3187-3198
DOI: 10.1002/mrm.70277 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 09.02.2026. Verfasst von Andreas Holl und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, Universi…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Enhancement, Signal Processing, Computer-Assisted, Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Carl-Zeiss-Stiftung.
Abstract (Originalsprache)
Purpose
Provide the theoretical foundation and the first practical demonstration of spatiotemporal encoding (SPEN) using additional nonlinear gradient hardware.
Methods
The quadratic phase profile can be generated either by a chirped‐RF pulse combined with a constant gradient or, directly, by a quadratic gradient pulse. Both a conventional chirped‐RF and a novel SPEN method using a custom‐built matrix gradient coil for quadratic phase generation were implemented and integrated into a spin‐echo echo‐planar‐imaging (SE‐EPI) sequence using Pulseq. The methods were compared through phantom imaging experiments performed on a 3T MRI system.
Results
The required quadratic phase profile for SPEN was successfully generated using the nonlinear gradient coil, resulting in images of comparable quality. This quadratic gradient‐based approach was achieved while exploiting the advantages of SPEN and overcoming current SAR and minimal TE limitations arising from the use of chirped‐RF pulses.
Conclusion
The generation of the SPEN‐defining quadratic phase using nonlinear gradients is an advantageous alternative to conventional methods. This approach enables improved clinical applicability of SPEN, particularly for 3D and high‐field MRI, by mitigating critical safety and timing limitations. Additionally, an implementation of the conventional method is provided open‐source to support further research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
- Department of Radiology and Nuclear Medicine, St Olav's University Hospital, Trondheim, Norway.
- Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering-IMTEK & BrainLinks-BrainTools Center, University of Freiburg, Freiburg, Germany.
- Department of Electrical Engineering & Information Technology, South Westphalia University of Applied Sciences, Lüdenscheid, Germany.
ORCID-Profile: Andreas Holl, Frank Zijlstra, Maxim Zaitsev, Jakob Hufschmidt, Shadi Tashakori, Nils Schallner, Thomas Stieglitz, Jens Gröbner, Sebastian Littin
Förderung
- Carl-Zeiss-Stiftung
Zitieren
APA
Holl, A., Zijlstra, F., Zaitsev, M., Hufschmidt, J., Tashakori, S., Schallner, N., Stieglitz, T., Gröbner, J., & Littin, S. (2026). Spatiotemporal Encoding With Nonlinear Gradient Hardware Using Pulseq: From Principles to Practical Demonstration. Magnetic Resonance in Medicine, 95(6), 3187-3198. https://doi.org/10.1002/mrm.70277
Vancouver
Holl A, Zijlstra F, Zaitsev M, Hufschmidt J, Tashakori S, Schallner N, et al. Spatiotemporal Encoding With Nonlinear Gradient Hardware Using Pulseq: From Principles to Practical Demonstration. Magnetic Resonance in Medicine. 2026;95(6):3187-3198. doi:10.1002/mrm.70277
BibTeX
@article{Holl2026,
author = {Holl, Andreas and Zijlstra, Frank and Zaitsev, Maxim and Hufschmidt, Jakob and Tashakori, Shadi and Schallner, Nils and Stieglitz, Thomas and Gröbner, Jens and Littin, Sebastian},
title = {Spatiotemporal Encoding With Nonlinear Gradient Hardware Using Pulseq: From Principles to Practical Demonstration},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {95},
number = {6},
pages = {3187--3198},
doi = {10.1002/mrm.70277}
}