EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optical Detuning Strategies for Shielded Loop Resonators

Jakob Gerlach iD, Reza Aghabagheri iD, Zining Liu, Shuai Liu iD, Morteza Teymoori, Çağlar Ataman, Michael Bock iD, Ali Caglar Özen iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70556 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Jakob Gerlach und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine - Un…. Hauptthemen laut MEDLINE: Transducers, Magnetic Resonance Imaging, Image Enhancement, Optical Devices. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare detuning performance and evaluate power requirements of optical detuning methods and to demonstrate feasibility of an optically‐detuned 4‐channel receive array.

Methods

Four optical detuning methods were compared in simulations, bench tests, and phantom measurements at 3T against conventional galvanic detuning. Passive detuning was also tested as an additional wireless detuning option. Optical power requirements for the detuning networks were investigated, and a flexible optically‐detuned 4‐channel shielded loop resonator (SLR) array was constructed and tested in vivo.

Results

A photodiode‐PIN diode combination exhibited the highest unloaded Q (68.6) and Q ratio (1.9), with detuning performance and signal‐to‐noise ratio comparable to that of galvanic detuning at an optical power of 10 mW. Using this detuning strategy, in vivo images of the knee and brain were successfully acquired with a 4‐channel flexible array.

Conclusion

Optical detuning is a practical alternative to conventional galvanic detuning in flexible SLR arrays. With developments in optical signal and power transmission, optimizing optical detuning while meeting manageable power requirements is an important step toward fully optical receive coil arrays. This study provides a reference point for the total optical power required for active detuning in such optical coil systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TransducersMagnetic Resonance ImagingImage EnhancementOptical DevicesEquipment DesignEquipment Failure AnalysisPhantoms, ImagingReproducibility of ResultsSensitivity and SpecificityHumansSignal-To-Noise RatioBrain

Stichwörter der Autor:innen

flexible receive arraylight coilsoptical detuningphotodiodeshielded loop resonator

Autor:innen und Institutionen

  • Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine - University of Freiburg, Freiburg, Germany.
  • Microsystems for Biomedical Imaging Group, Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany.

ORCID-Profile: Jakob Gerlach, Reza Aghabagheri, Shuai Liu, Michael Bock, Ali Caglar Özen

Förderung

  • Deutsche Forschungsgemeinschaft

Zitieren

APA

Gerlach, J., Aghabagheri, R., Liu, Z., Liu, S., Teymoori, M., Ataman, Ç., Bock, M., & Özen, A. C. (2026). Optical Detuning Strategies for Shielded Loop Resonators. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70556

Vancouver

Gerlach J, Aghabagheri R, Liu Z, Liu S, Teymoori M, Ataman Ç, et al. Optical Detuning Strategies for Shielded Loop Resonators. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70556

BibTeX
@article{Gerlach2026,
  author = {Gerlach, Jakob and Aghabagheri, Reza and Liu, Zining and Liu, Shuai and Teymoori, Morteza and Ataman, Çağlar and Bock, Michael and Özen, Ali Caglar},
  title = {Optical Detuning Strategies for Shielded Loop Resonators},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70556}
}
Kostenlos starten →