Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 17.09.2026. Verfasst von Jacopo Frignani und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, TUM School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Algorithms, Image Enhancement, Image Interpretation, Computer-Assisted. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bayerische Akademie der Wissenschaften, Deutsche Forschungsgemeinschaft.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Starting from the implementation of a single‐slice FEXI sequence, a 3D method was developed to accelerate a FEXI experiment and acquire a multi‐slice volume.

Methods

3D multi‐slab FEXI divides the volume of interest into different slabs. In each slab, the slab‐selective diffusion and exchange modules are combined with slice‐selective detection modules. The 3D multi‐slab FEXI acquisition speed was assessed against single‐ and multi‐slice FEXI. In addition, the new method was compared to single‐slice FEXI on a yeast phantom.

Results

3D multi‐slab FEXI acquires thirty slices within the same scan time required for single‐ and multi‐slice FEXI to acquire one and five slices, respectively. 3D multi‐slab FEXI found AXR values, homogeneity, repeatability, and reproducibility comparable to those of single‐slice FEXI, increasing SNR efficiency.

Conclusion

3D multi‐slab FEXI accelerates a FEXI experiment and acquires a volume of several slices in the same scan time as the single‐slice FEXI protocol, giving comparable AXRs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalAlgorithmsImage EnhancementImage Interpretation, Computer-AssistedMagnetic Resonance ImagingReproducibility of ResultsSensitivity and SpecificityPhantoms, Imaging

Stichwörter der Autor:innen

3D imagingAXRFEXIaccelerationslab

Autor:innen und Institutionen

  • Department of Nuclear Medicine, TUM School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.
  • CT-MRI Department, Hygeia Hospital, Athens, Greece.
  • Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany.

ORCID-Profile: Franz Schilling

Förderung

  • Bayerische Akademie der Wissenschaften
  • Deutsche Forschungsgemeinschaft

Zitieren

APA

Frignani, J., Kaika, A., Danzer, B., & Schilling, F. (2027). Enhanced 3D Filter‐Exchange Imaging Using Multi‐Slab Acquisition. Magnetic Resonance in Medicine, 97(1), 269-275. https://doi.org/10.1002/mrm.70593

Vancouver

Frignani J, Kaika A, Danzer B, Schilling F. Enhanced 3D Filter‐Exchange Imaging Using Multi‐Slab Acquisition. Magnetic Resonance in Medicine. 2027;97(1):269-275. doi:10.1002/mrm.70593

BibTeX
@article{Frignani2027,
  author = {Frignani, Jacopo and Kaika, Athanasia and Danzer, Ben and Schilling, Franz},
  title = {Enhanced 3D Filter‐Exchange Imaging Using Multi‐Slab Acquisition},
  journal = {Magnetic Resonance in Medicine},
  year = {2027},
  volume = {97},
  number = {1},
  pages = {269--275},
  doi = {10.1002/mrm.70593}
}
Kostenlos starten →