Incomplete Spoiling Correction for 3D T1 Mapping
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70559 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Gabriela Belsley und 3 weiteren Autor:innen. Beteiligte Einrichtung: Oxford Centre for Clinical Magnetic Resonance Research, Radcliffe Department of Medicine, University of Oxford, Oxford, UK. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Imaging, Three-Dimensional, Image Enhancement, Image Interpretation, Computer-Assisted. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council (EPSRC), NIHR Oxford Biomedical Research Centre, Medical Research Council.
Abstract (Originalsprache)
Purpose
Assess the impact of incomplete spoiling and spatial saturation on mapping using the variable flip angle (VFA) spoiled gradient recalled echo sequence (SPGR). Develop a correction for incomplete spoiling that results in an accurate estimate of , essential for quantitative MRI applications.
Methods
A correction factor, derived from extended phase graph simulations, was applied to the measured SPGR signal to account for deviations from the theoretical steady‐state signal. An iterative fitting process was used, refining the incomplete spoiling correction factor at each step based on the updated estimate. The incomplete spoiling correction method was validated against inversion recovery spin echo in phantom experiments and applied to in vivo data at 3T. Additionally, the hypothesis that spatial saturation disrupts the steady‐state was also tested and validated in a phantom.
Results
Without a correction, the median error was +7.4% (IQR [4.4, 9.6]%) in both simulations and phantom experiments. After applying the correction, the median error decreased to −0.3% (IQR [−2.5, 2.1]%). In vivo, incomplete spoiling caused overestimation of 10–50 ms depending on inhomogeneity. Spatial saturation induced on average a −10% bias.
Conclusion
A correction for incomplete spoiling is essential to achieve an accurate measure of using the VFA SPGR method, addressing systematic overestimation when using this mapping technique. Furthermore, other mechanisms that may disrupt the steady‐state signal, such as spatial saturation, should be considered.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Oxford Centre for Clinical Magnetic Resonance Research, Radcliffe Department of Medicine, University of Oxford, Oxford, UK.
- Perspectum, Oxford, UK.
ORCID-Profile: Gabriela Belsley, Matthew D Robson
Förderung
- Engineering and Physical Sciences Research Council (EPSRC)
- NIHR Oxford Biomedical Research Centre
- Medical Research Council
Zitieren
APA
Belsley, G., Tyler, D. J., Robson, M. D., & Tunnicliffe, E. M. (2026). Incomplete Spoiling Correction for 3D T1 Mapping. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70559
Vancouver
Belsley G, Tyler DJ, Robson MD, Tunnicliffe EM. Incomplete Spoiling Correction for 3D T1 Mapping. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70559
BibTeX
@article{Belsley2026,
author = {Belsley, Gabriela and Tyler, Damian J and Robson, Matthew D and Tunnicliffe, Elizabeth M},
title = {Incomplete Spoiling Correction for 3D T1 Mapping},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70559}
}
EUVIMED