Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Morgane Garreau und 6 weiteren Autor:innen. Beteiligte Einrichtung: IMAG, University of Montpellier, CNRS, Montpellier, France. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Image Interpretation, Computer-Assisted, Models, Cardiovascular, Aorta. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: MESO@LR-Platform at the University of Montpellier, GENCI-CINES.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim of this study is to investigate the impact of the partial echo on 4D flow MRI sequences thanks to in silico coupled MRI‐CFD (computational fluid dynamics) simulations.

Methods

Two sequences are studied: one with a full echo (FE) and another using partial echo (PE) with an echo symmetry fraction of 0.75. MRI‐CFD simulations are conducted on an in silico pulsatile flow phantom for a sinusoidal inflow and a physiological inflow typical of the ascending aorta.

Results

For both inflow signals, PE‐based simulations exhibited better compliance with their matching CFD simulations compared to the FE ones.

Conclusion

The reduction of flow misregistration artifacts achieved through the use of PE appears to be more beneficial than the drawback of incomplete k‐space filling. The MRI‐CFD framework presented in this study appears as a useful tool to investigate the design of MRI sequences and to stratify its different sources of errors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalImage Interpretation, Computer-AssistedModels, CardiovascularAortaMagnetic Resonance ImagingMagnetic Resonance AngiographyComputer SimulationBlood Flow VelocityReproducibility of ResultsImage EnhancementHumansAlgorithmsSensitivity and SpecificityPhantoms, Imaging

Stichwörter der Autor:innen

4D flowcomputational fluid dynamics (CFD)numerical simulationpartial echo (PE)

Autor:innen und Institutionen

  • IMAG, University of Montpellier, CNRS, Montpellier, France.
  • Spin Up, ALARA Group, Strasbourg, France.
  • INRIA Saclay, Palaiseau, France.
  • I2MC, INSERM/UPS UMR 1297, Toulouse, France.
  • ALARA Expertise, ALARA Group, Strasbourg, France.
  • Siemens Healthineers France, Saint-Denis, France.

ORCID-Profile: Morgane Garreau, Thomas Puiseux, Ramiro Moreno, Solenn Toupin, Daniel Giese, Franck Nicoud, Simon Mendez

Förderung

  • MESO@LR-Platform at the University of Montpellier
  • GENCI-CINES

Zitieren

APA

Garreau, M., Puiseux, T., Moreno, R., Toupin, S., Giese, D., Nicoud, F., & Mendez, S. (2026). Impact of Partial Echo on 4D Flow MRI: The Insight From Synthetic MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70260

Vancouver

Garreau M, Puiseux T, Moreno R, Toupin S, Giese D, Nicoud F, et al. Impact of Partial Echo on 4D Flow MRI: The Insight From Synthetic MRI. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70260

BibTeX
@article{Garreau2026,
  author = {Garreau, Morgane and Puiseux, Thomas and Moreno, Ramiro and Toupin, Solenn and Giese, Daniel and Nicoud, Franck and Mendez, Simon},
  title = {Impact of Partial Echo on 4D Flow MRI: The Insight From Synthetic MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70260}
}
Kostenlos starten →