Enhanced 3D Filter‐Exchange Imaging Using Multi‐Slab Acquisition
Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 269-275
DOI: 10.1002/mrm.70593 ↗At a glance
Journal article in Magnetic Resonance in Medicine, published online on 2026-09-17. Written by Jacopo Frignani and 3 co-authors. Institution: Department of Nuclear Medicine, TUM School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany. Major MEDLINE topics: Imaging, Three-Dimensional, Algorithms, Image Enhancement, Image Interpretation, Computer-Assisted. 21 references. The full text is freely available (open access, CC BY 4.0). Funded by: Bayerische Akademie der Wissenschaften, Deutsche Forschungsgemeinschaft.
Abstract (original language)
Purpose
Starting from the implementation of a single‐slice FEXI sequence, a 3D method was developed to accelerate a FEXI experiment and acquire a multi‐slice volume.
Methods
3D multi‐slab FEXI divides the volume of interest into different slabs. In each slab, the slab‐selective diffusion and exchange modules are combined with slice‐selective detection modules. The 3D multi‐slab FEXI acquisition speed was assessed against single‐ and multi‐slice FEXI. In addition, the new method was compared to single‐slice FEXI on a yeast phantom.
Results
3D multi‐slab FEXI acquires thirty slices within the same scan time required for single‐ and multi‐slice FEXI to acquire one and five slices, respectively. 3D multi‐slab FEXI found AXR values, homogeneity, repeatability, and reproducibility comparable to those of single‐slice FEXI, increasing SNR efficiency.
Conclusion
3D multi‐slab FEXI accelerates a FEXI experiment and acquires a volume of several slices in the same scan time as the single‐slice FEXI protocol, giving comparable AXRs.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Nuclear Medicine, TUM School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.
- CT-MRI Department, Hygeia Hospital, Athens, Greece.
- Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany.
ORCID profiles: Franz Schilling
Funding
- Bayerische Akademie der Wissenschaften
- Deutsche Forschungsgemeinschaft
Cite
APA
Frignani, J., Kaika, A., Danzer, B., & Schilling, F. (2027). Enhanced 3D Filter‐Exchange Imaging Using Multi‐Slab Acquisition. Magnetic Resonance in Medicine, 97(1), 269-275. https://doi.org/10.1002/mrm.70593
Vancouver
Frignani J, Kaika A, Danzer B, Schilling F. Enhanced 3D Filter‐Exchange Imaging Using Multi‐Slab Acquisition. Magnetic Resonance in Medicine. 2027;97(1):269-275. doi:10.1002/mrm.70593
BibTeX
@article{Frignani2027,
author = {Frignani, Jacopo and Kaika, Athanasia and Danzer, Ben and Schilling, Franz},
title = {Enhanced 3D Filter‐Exchange Imaging Using Multi‐Slab Acquisition},
journal = {Magnetic Resonance in Medicine},
year = {2027},
volume = {97},
number = {1},
pages = {269--275},
doi = {10.1002/mrm.70593}
}
EUVIMED