EUVIMEDEUVIMED entdecken
Crossref

Echo‐Planar‐Based Time‐of‐Flight Imaging Using a Modified Interleaved Flyback Trajectory

Simon Blömer iD, Tony Stöcker iD, Rüdiger Stirnberg iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70272 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Simon Blömer und 2 weiteren Autor:innen. Beteiligte Einrichtung: German Center for Neurodegenerative Diseases (DZNE), Bonn, Germany. Hauptthemen laut MEDLINE: Echo-Planar Imaging, Image Enhancement, Imaging, Three-Dimensional, Image Interpretation, Computer-Assisted. Die Arbeit nennt 40 Literaturangaben. Gefördert von: Helmholtz Association, Initiative and Networking Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

A modified interleaved flyback (miFB) approach is introduced, designed to mitigate flow artifacts caused by alternating readout polarities in Echo Planar Imaging (EPI), while preserving acquisition efficiency.

Methods

We propose reconstructing odd and even echoes of 3D‐EPI separately. To this end, the respective missing lines are acquired in interleaved shots with inverted polarity and an additional gradient pre‐lobe. Thereby, high scan efficiency is maintained compared to unsampled flyback gradients. Our miFB approach is additionally combined with gradient moment smoothing and compared to the interleaved dual‐echo with acceleration (IDEA) method in phantom and in vivo scans at 7 Tesla.

Results

Our results demonstrate a significant reduction in ghosting and signal dropout using the miFB approach, yielding comparable image quality to non‐EPI acquisitions while reducing acquisition time by approximately half.

Conclusion

The miFB approach offers a substantial reduction in flow artifacts, allowing for decreased acquisition times in TOF‐MRA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echo-Planar ImagingImage EnhancementImaging, Three-DimensionalImage Interpretation, Computer-AssistedMagnetic Resonance AngiographyHumansAlgorithmsArtifactsSensitivity and SpecificityReproducibility of ResultsPhantoms, Imaging

Stichwörter der Autor:innen

3D‐EPI7Techo planar imagingflow artifactsmagnetic resonance angiography

Autor:innen und Institutionen

  • German Center for Neurodegenerative Diseases (DZNE), Bonn, Germany.
  • Department of Physics and Astronomy, University of Bonn, Bonn, Germany.

ORCID-Profile: Simon Blömer, Tony Stöcker, Rüdiger Stirnberg

Förderung

  • Helmholtz Association, Initiative and Networking Fund

Zitieren

APA

Blömer, S., Stöcker, T., & Stirnberg, R. (2026). Echo‐Planar‐Based Time‐of‐Flight Imaging Using a Modified Interleaved Flyback Trajectory. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70272

Vancouver

Blömer S, Stöcker T, Stirnberg R. Echo‐Planar‐Based Time‐of‐Flight Imaging Using a Modified Interleaved Flyback Trajectory. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70272

BibTeX
@article{Blmer2026,
  author = {Blömer, Simon and Stöcker, Tony and Stirnberg, Rüdiger},
  title = {Echo‐Planar‐Based Time‐of‐Flight Imaging Using a Modified Interleaved Flyback Trajectory},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70272}
}
Kostenlos starten →