A Rapid T 1 ‐Independent Sequence for Cerebrospinal Fluid Water Standard Correction: Application to Improved Proton Density Mapping in Brain
Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 259-268
DOI: 10.1002/mrm.70589 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 14.09.2026. Verfasst von Kiarash Jalali und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada. Hauptthemen laut MEDLINE: Brain, Echo-Planar Imaging, Cerebrospinal Fluid, Water. Die Arbeit nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: CIHR, Natural Sciences and Engineering Research Council of Canada, Canadian Institutes of Health Research.
Abstract (Originalsprache)
Purpose
To improve brain water content measures relative to cerebrospinal fluid (CSF) by including a rapid T 1 ‐independent sequence to correct for CSF T 1 errors.
Methods
Proton density (PD) was estimated from a 3D multiple echo gradient echo sequence by extrapolating to TE = 0 and then correcting for T 1 losses using a T 1 map from 3D MP2RAGE. To overcome errors in CSF T 1 , a T 1 ‐independent single‐shot echo planar imaging (EPI) sequence was introduced to determine the CSF‐to‐tissue signal ratio and then rescale the resulting relative PD map into a quantitative measurement. The technique is demonstrated in phantom and five healthy subjects. In addition to producing PD scaled to CSF water content, the method enables calculation of CSF T 1 .
Results
Phantom experiments confirmed the validity of the approach, reducing T 1 error after EPI correction from 54.2% to 1.0% in comparison with an inversion recovery (IR) gold standard. In five healthy subjects, the average CSF reference correction factor was 1.48, and the mean CSF T 1 error was reduced from (45.8% ± 0.8%) down to (1.1% ± 0.5%) compared to the IR gold standard. Regional PD measurements within the human brain were in agreement with previous literature.
Conclusion
Introduction of a rapid T 1 ‐independent sequence enabled correction of CSF‐referenced PD maps, avoiding the difficulty of direct CSF T 1 measurement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada.
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada.
ORCID-Profile: Kiarash Jalali, Nashwan Naji
Förderung
- CIHR
- Natural Sciences and Engineering Research Council of Canada
- Canadian Institutes of Health Research
Zitieren
APA
Jalali, K., Naji, N., Seres, P., & Wilman, A. H. (2027). A Rapid T 1 ‐Independent Sequence for Cerebrospinal Fluid Water Standard Correction: Application to Improved Proton Density Mapping in Brain. Magnetic Resonance in Medicine, 97(1), 259-268. https://doi.org/10.1002/mrm.70589
Vancouver
Jalali K, Naji N, Seres P, Wilman AH. A Rapid T 1 ‐Independent Sequence for Cerebrospinal Fluid Water Standard Correction: Application to Improved Proton Density Mapping in Brain. Magnetic Resonance in Medicine. 2027;97(1):259-268. doi:10.1002/mrm.70589
BibTeX
@article{Jalali2027,
author = {Jalali, Kiarash and Naji, Nashwan and Seres, Peter and Wilman, Alan H},
title = {A Rapid T 1 ‐Independent Sequence for Cerebrospinal Fluid Water Standard Correction: Application to Improved Proton Density Mapping in Brain},
journal = {Magnetic Resonance in Medicine},
year = {2027},
volume = {97},
number = {1},
pages = {259--268},
doi = {10.1002/mrm.70589}
}
EUVIMED