EUVIMEDEUVIMED entdecken
Open Access

Time‐resolved MR fingerprinting for T 2 * signal extraction: MR fingerprinting meets echo planar time‐resolved imaging

Di Cui iD, Xiaoxi Liu iD, Peder E Z Larson iD, Duan Xu

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30381 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Di Cui und 3 weiteren Autor:innen. Beteiligte Einrichtung: Radiology & Biomedical Imaging, University of California San Francisco, San Francisco, California, USA. Hauptthemen laut MEDLINE: Echo-Planar Imaging, Brain, Image Processing, Computer-Assisted, Magnetic Resonance Imaging. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, University of California, San Francisco, Department of Radiology & Biomedical Imaging, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study leverages the echo planar time‐resolved imaging (EPTI) concept in MR fingerprinting (MRF) framework for a new time‐resolved MRF (TRMRF) approach, and explores its capability for fast simultaneous quantification of multiple MR parameters including T 1 , T 2 , T 2 *, proton density, off resonance, and B 1 + .

Methods

The proposed TRMRF method uses the concept of EPTI to track the signal change along the EPI echo train for T 2 * weighting with a k‐t Poisson‐based sampling order designed for acquisition. A two‐dimensional decomposition algorithm was designed for the image reconstruction, enabling fast and precise subspace modeling. The accuracy of proposed method was evaluated by a T 1 /T 2 phantom. The feasibility was demonstrated through 5 healthy volunteer brain studies.

Results

In the phantom studies, T 1 , T 2 , and T 2 * maps of TRMRF correlated strongly with gold‐standard methods. The concordance correlation coefficients are 0.9999, 0.9984 and 0.9978, and R 2 s are 0.9998, 0.9971, and 0.9983. In the in vivo studies, quantitative maps were acquired with 5 healthy volunteers. TRMRF was demonstrated to have comparable results with spiral MRF and gradient‐echo EPTI. TRMRF scans using 16, 10, and 6 s per slice were also evaluated to demonstrate the capability of shorter scan times.

Conclusion

A new approach is proposed to exploit the advantage of EPTI in the MRF framework. We demonstrate in phantom and in vivo experiments that T 1 , T 2 , T 2 *, proton density, off resonance, and B 1 + can be simultaneously quantified within 6 s/slice by TRMRF.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echo-Planar ImagingBrainImage Processing, Computer-AssistedMagnetic Resonance ImagingHumansPhantoms, ImagingAlgorithmsHealthy VolunteersAdultMaleReproducibility of Results

Stichwörter der Autor:innen

MR fingerprintingT2*echo planar time‐resolved imagingquantitative MRI

Autor:innen und Institutionen

  • Radiology & Biomedical Imaging, University of California San Francisco, San Francisco, California, USA.
  • Graduate Program in Bioengineering, University of California, Berkeley and San Francisco, San Francisco, California, USA.

ORCID-Profile: Di Cui, Xiaoxi Liu, Peder E Z Larson

Förderung

  • NIBIB NIH HHS
  • University of California, San Francisco, Department of Radiology & Biomedical Imaging
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Cui, D., Liu, X., Larson, P. E. Z., & Xu, D. (2025). Time‐resolved MR fingerprinting for T 2 * signal extraction: MR fingerprinting meets echo planar time‐resolved imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30381

Vancouver

Cui D, Liu X, Larson PEZ, Xu D. Time‐resolved MR fingerprinting for T 2 * signal extraction: MR fingerprinting meets echo planar time‐resolved imaging. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30381

BibTeX
@article{Cui2025,
  author = {Cui, Di and Liu, Xiaoxi and Larson, Peder E Z and Xu, Duan},
  title = {Time‐resolved MR fingerprinting for T 2 * signal extraction: MR fingerprinting meets echo planar time‐resolved imaging},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30381}
}
Kostenlos starten →