Accelerated multi-b-value multi-shot diffusion-weighted imaging based on EPI with keyhole and a low-rank tensor constraint
Magnetic Resonance Imaging · 2024
DOI: 10.1016/j.mri.2024.04.015 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Xin Tang und 6 weiteren Autor:innen. Beteiligte Einrichtung: National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shangha…. Hauptthemen laut MEDLINE: Algorithms, Echo-Planar Imaging, Diffusion Magnetic Resonance Imaging, Phantoms, Imaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Commission of Shanghai Municipality.
Abstract (Originalsprache)
PURPOSE: Multi-Shot (MS) Echo-Planar Imaging (EPI) may improve the in-plane resolution of multi-b-value DWI, yet it also considerably increases the scan time. Here we explored the combination of EPI with Keyhole (EPIK) and a calibrationless reconstruction algorithm for acceleration of multi-b-value MS-DWI. METHODS: We firstly analyzed the impact of nonuniform phase accrual in EPIK on the reconstructed image. Based on insights gained from the analysis, we developed a calibrationless reconstruction algorithm based on a Space-Contrast-Coil Locally Low-Rank Tensor (SCC-LLRT) constraint for reconstruction of EPIK-acquired data. We compared the algorithm with a modified SPatial-Angular Locally Low-Rank (SPA-LLR) algorithm through simulations, phantoms, and in vivo study. We then compared EPIK with uniformly undersampled EPI for accelerating multi-b-value DWI in 6 healthy subjects. RESULTS: Through theoretical derivations, we found that the reconstruction of EPIK with a SENSE-encoding-based algorithm, such as SPA-LLR, may cause additional aliasing artifacts due to the frequency-dependent distortion of the coil sensitivity. Results from simulations, phantoms, and in vivo study verified the theoretical finding by showing that the calibrationless SCC-LLRT algorithm reduced aliasing artifacts compared with SPA-LLR. Finally, EPIK with SCC-LLRT substantially reduced the ghosting artifacts compared with uniform undersampled multi-b-value DWI, decreasing the fitting errors in ADC (0.05 ± 0.01 vs 0.10 ± 0.01, P < 0.001) and IVIM mapping (0.026 ± 0.004 vs 0.06 ± 0.006, P < 0.001). CONCLUSION: The SCC-LLRT algorithm reduced the aliasing artifacts of EPIK by using a calibrationless modeling of the multi-coil data. The dense sampling of k-space center offers EPIK a potential to improve image quality for acceleration of multi-b-value MS-DWI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China; United Imaging Healthcare Co.…
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
- Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China.
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. Electronic address: chenxi.hu…
Förderung
- National Natural Science Foundation of China
- Science and Technology Commission of Shanghai Municipality
Zitieren
APA
Tang, X., Gao, J., Aburas, A., Wu, D., Chen, Z., Chen, H., & Hu, C. (2024). Accelerated multi-b-value multi-shot diffusion-weighted imaging based on EPI with keyhole and a low-rank tensor constraint. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.04.015
Vancouver
Tang X, Gao J, Aburas A, Wu D, Chen Z, Chen H, et al. Accelerated multi-b-value multi-shot diffusion-weighted imaging based on EPI with keyhole and a low-rank tensor constraint. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.04.015
BibTeX
@article{Tang2024,
author = {Tang, Xin and Gao, Juan and Aburas, Ahmed and Wu, Dan and Chen, Zhuo and Chen, Hao and Hu, Chenxi},
title = {Accelerated multi-b-value multi-shot diffusion-weighted imaging based on EPI with keyhole and a low-rank tensor constraint},
journal = {Magnetic Resonance Imaging},
year = {2024},
doi = {10.1016/j.mri.2024.04.015}
}