Phase‐Sensitive Modeling Improves Fat DESPOT Multiparametric Relaxation Mapping in Fat‐Water Mixtures
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70516 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2026. Written by Renée-Claude Bider and 5 co-authors. Institution: Medical Physics Unit, McGill University, Montréal, Québec, Canada. Major MEDLINE topics: Adipose Tissue, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. 62 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Natural Sciences and Engineering Research Council of Canada (NSERC), Fonds de Recherche du Québec - Santé, Research Institute of the McGill University Health Centre.
Abstract (original language)
Purpose
To improve on a multiparametric technique—known as Fat DESPOT—to map the fat‐ and water‐specific (, ), , and proton density fat fraction (PDFF) by upgrading the parameter initialization and introducing explicit model sensitivity to the complex phase of the water and fat signals.
Methods
We compared three‐point Dixon and Graph Cut (GC) approaches to initial guesses for Fat DESPOT in experiments at 3 T in fat emulsion phantoms. Also in the phantom, we compared magnitude‐based Fat DESPOT (Fat DESPOT m ) to a magnitude approach modeling the phases of fat and water separately (Fat DESPOT mϕ ), and two models for complex data (Fat DESPOT c , Fat DESPOT cϕ ). The complex approaches, which performed best, were used in the lower leg and abdomen of healthy human participants.
Results
In phantoms, Fat DESPOT using three‐point Dixon and GC returned similar parameter estimates and precision, though the former deviated from the overall trend at 50% nominal fat fraction. The complex models showed the best agreement with reference PDFF (average error 1.2% ± 1.2%) and the lowest combined standard deviation across ROIs, for PDFF, , and (maximum = 0.13%, 0.19 s −1 , and 0.009 s −1 , respectively).
Conclusion
With more precise and , more accurate PDFF, and more versatile echo time selection, this work demonstrates the advantages of Fat DESPOT multiparametric mapping with complex fitting and GC‐based parameter initialization.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Medical Physics Unit, McGill University, Montréal, Québec, Canada.
- Department of Physics, McGill University, Montréal, Québec, Canada.
- Medical Imaging, McGill University Health Centre, Montréal, Québec, Canada.
- Department of Diagnostic Radiology, McGill University, Montréal, Québec, Canada.
- Gerald Bronfman Department of Oncology, McGill University, Montréal, Québec, Canada.
- Medical Physics, McGill University Health Centre, Montréal, Québec, Canada.
ORCID profiles: Véronique Fortier, Ives R Levesque
Funding
- Natural Sciences and Engineering Research Council of Canada (NSERC)
- Fonds de Recherche du Québec - Santé
- Research Institute of the McGill University Health Centre
- Institut de recherche, Centre universitaire de santé McGill
Cite
APA
Bider, R. C., Ciobanu, C., Campos Pazmiño, J., Fortier, V., McNabb, E., & Levesque, I. R. (2026). Phase‐Sensitive Modeling Improves Fat DESPOT Multiparametric Relaxation Mapping in Fat‐Water Mixtures. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70516
Vancouver
Bider RC, Ciobanu C, Campos Pazmiño J, Fortier V, McNabb E, Levesque IR. Phase‐Sensitive Modeling Improves Fat DESPOT Multiparametric Relaxation Mapping in Fat‐Water Mixtures. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70516
BibTeX
@article{Bider2026,
author = {Bider, Renée-Claude and Ciobanu, Cristian and Campos Pazmiño, Jorge and Fortier, Véronique and McNabb, Evan and Levesque, Ives R},
title = {Phase‐Sensitive Modeling Improves Fat DESPOT Multiparametric Relaxation Mapping in Fat‐Water Mixtures},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70516}
}
EUVIMED