3D B1 + corrected simultaneous myocardial T1 and T1 ρ mapping with subject‐specific respiratory motion correction and water‐fat separation
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30317 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Haikun Qi und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai, China. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Phantoms, Imaging, Heart, Adipose Tissue. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shanghai Science and Technology Commission, Cross-disciplinary Research Fund of Shanghai Ninth People's Hospital, Shanghai JiaoTong university School of Medicine.
Abstract (Originalsprache)
Purpose
To develop a 3D free‐breathing cardiac multi‐parametric mapping framework that is robust to confounders of respiratory motion, fat, and B1+ inhomogeneities and validate it for joint myocardial T1 and T1ρ mapping at 3T.
Methods
An electrocardiogram‐triggered sequence with dual‐echo Dixon readout was developed, where nine cardiac cycles were repeatedly acquired with inversion recovery and T1ρ preparation pulses for T1 and T1ρ sensitization. A subject‐specific respiratory motion model relating the 1D diaphragmatic navigator to the respiration‐induced 3D translational motion of the heart was constructed followed by respiratory motion binning and intra‐bin 3D translational and inter‐bin non‐rigid motion correction. Spin history B1+ inhomogeneities were corrected with optimized dual flip angle strategy. After water‐fat separation, the water images were matched to the simulated dictionary for T1 and T1ρ quantification. Phantoms and 10 heathy subjects were imaged to validate the proposed technique.
Results
The proposed technique achieved strong correlation (T1: R 2 = 0.99; T1ρ: R 2 = 0.98) with the reference measurements in phantoms. 3D cardiac T1 and T1ρ maps with spatial resolution of 2 × 2 × 4 mm were obtained with scan time of 5.4 ± 0.5 min, demonstrating comparable T1 (1236 ± 59 ms) and T1ρ (50.2 ± 2.4 ms) measurements to 2D separate breath‐hold mapping techniques. The estimated B1+ maps showed spatial variations across the left ventricle with the septal and inferior regions being 10%–25% lower than the anterior and septal regions.
Conclusion
The proposed technique achieved efficient 3D joint myocardial T1 and T1ρ mapping at 3T with respiratory motion correction, spin history B1+ correction and water‐fat separation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai, China.
- Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
- United Imaging Healthcare, Shanghai, China.
- UIH America, Inc., Houston, Texas, USA.
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
- School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.
ORCID-Profile: Haikun Qi, Jiameng Diao
Förderung
- National Natural Science Foundation of China
- Shanghai Science and Technology Commission
- Cross-disciplinary Research Fund of Shanghai Ninth People's Hospital, Shanghai JiaoTong university School of Medicine
Zitieren
APA
Qi, H., Lv, Z., Diao, J., Tao, X., Hu, J., Xu, J., Botnar, R., Prieto, C., & Hu, P. (2025). 3D B1 + corrected simultaneous myocardial T1 and T1 ρ mapping with subject‐specific respiratory motion correction and water‐fat separation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30317
Vancouver
Qi H, Lv Z, Diao J, Tao X, Hu J, Xu J, et al. 3D B1 + corrected simultaneous myocardial T1 and T1 ρ mapping with subject‐specific respiratory motion correction and water‐fat separation. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30317
BibTeX
@article{Qi2025,
author = {Qi, Haikun and Lv, Zhenfeng and Diao, Jiameng and Tao, Xiaofeng and Hu, Junpu and Xu, Jian and Botnar, René and Prieto, Claudia and Hu, Peng},
title = {3D B1 + corrected simultaneous myocardial T1 and T1 ρ mapping with subject‐specific respiratory motion correction and water‐fat separation},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30317}
}
EUVIMED