EUVIMEDEUVIMED entdecken
Crossref

A flexible framework for the design and optimization of water‐excitation RF pulses using B‐spline interpolation

Xavier Sieber iD, Ludovica Romanin iD, Jessica A M Bastiaansen iD, Christopher W Roy iD, Jérôme Yerly, Daniel Wenz iD, Jonas Richiardi iD, Matthias Stuber iD, Ruud B van Heeswijk iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30390 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Xavier Sieber und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Water, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Swiss National Science Foundation, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To implement a flexible framework, named HydrOptiFrame, for the design and optimization of time‐efficient water‐excitation (WE) RF pulses using B‐spline interpolation, and to characterize their lipid suppression performance.

Methods

An evolutionary optimization algorithm was used to design WE RF pulses. The algorithm minimizes a composite loss function that quantifies the fat–water contrast using Bloch equation simulations. In a first study, B‐spline interpolated optimized (BSIO) pulses designed with HydrOptiFrame with durations of 1 and 0.76 ms were generated for 3 T and characterized in healthy volunteers' knees. The femoral bone marrow SNR was compared to that obtained with to 1–1 WE and lipid insensitive binomial off resonant excitation (LIBRE) pulses. In a second study, in the heart at 1.5 T, the water–fat contrast ratio and coronary artery vessel length obtained with a 2.56 ms BSIO pulse was compared to 1–1 WE and LIBRE pulses in free‐running cardiovascular MR.

Results

The 1 ms BSIO pulse resulted in higher fat suppression and lower contrast ratio (CR) in the bone marrow than the state‐of‐the‐art pulses (4.1 ± 0.2 vs. 4.7 ± 0.4 and 4.4 ± 0.3 for the BSIO, the 1–1 WE and LIBRE respectively, p < 0.05 vs. both) at 3 T. At 1.5 T, the BSIO pulse resulted in a higher blood‐epicardial fat CR (3.8 ± 1.3 vs. 1.6 ± 0.6 and 2.4 ± 1.1 for the BSIO, 1–1 WE and LIBRE, respectively, p < 0.05 vs. both) and longer traceable left coronary artery vessel length (8.7 ± 1.4 cm vs. 7.0 ± 1.0 cm [ p = 0.04] and 7.5 ± 1.2 cm [ p = 0.09]).

Conclusion

The HydrOptiFrame framework offers a new opportunity to design WE RF pulses that are robust to B 0 inhomogeneity at multiple magnetic field strengths and for variable RF pulse durations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingWaterImage Processing, Computer-AssistedHumansAlgorithmsAdultHeartMaleCoronary VesselsKneeAdipose TissueSignal-To-Noise RatioFemalePhantoms, ImagingBone MarrowRadio WavesLipids

Stichwörter der Autor:innen

5D whole‐heart cardiovascular MRIRF pulse designWE pulsefat suppressionfree‐runningfree‐running cardiac imagingnumerical optimizationwater‐excitation

Substanzen

WaterLipids

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.
  • Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland.
  • Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland.
  • CIBM Center for Biomedical Imaging, Lausanne, Switzerland.
  • CIBM Animal Imaging and Technology, EPFL, Lausanne, Switzerland.

ORCID-Profile: Xavier Sieber, Ludovica Romanin, Jessica A M Bastiaansen, Christopher W Roy, Daniel Wenz, Jonas Richiardi, Matthias Stuber, Ruud B van Heeswijk

Förderung

  • Swiss National Science Foundation
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Zitieren

APA

Sieber, X., Romanin, L., Bastiaansen, J. A. M., Roy, C. W., Yerly, J., Wenz, D., Richiardi, J., Stuber, M., & van Heeswijk, R. B. (2025). A flexible framework for the design and optimization of water‐excitation RF pulses using B‐spline interpolation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30390

Vancouver

Sieber X, Romanin L, Bastiaansen JAM, Roy CW, Yerly J, Wenz D, et al. A flexible framework for the design and optimization of water‐excitation RF pulses using B‐spline interpolation. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30390

BibTeX
@article{Sieber2025,
  author = {Sieber, Xavier and Romanin, Ludovica and Bastiaansen, Jessica A M and Roy, Christopher W and Yerly, Jérôme and Wenz, Daniel and Richiardi, Jonas and Stuber, Matthias and van Heeswijk, Ruud B},
  title = {A flexible framework for the design and optimization of water‐excitation RF pulses using B‐spline interpolation},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30390}
}
Kostenlos starten →