EUVIMEDSkopri EUVIMED
Open access · CC BY 4.0

View Order With Arbitrary Center Echoes

Henric Rydén iD, Ola Norbeck iD, Sophie Schauman iD, Mikael Skorpil iD, Adam van Niekerk iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70482 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2026. Written by Henric Rydén and 4 co-authors. Institution: Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden. Major MEDLINE topics: Algorithms, Image Enhancement, Magnetic Resonance Imaging, Image Interpretation, Computer-Assisted. 26 references. The full text is freely available (open access, CC BY 4.0).

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Purpose

To provide explicit, vendor‐independent view‐order constructions that enable selection of an arbitrary center echo in multi‐shot imaging, with a focus on RARE and MPRAGE.

Methods

Vendor‐independent view‐order methods were developed to assign echo and shot indices to a prescribed set of phase encodes, enabling explicit selection of the center echo and avoiding large discontinuities near k‐space center. The view‐order methods were implemented in 2D RARE, 3D RARE, and MPRAGE, and evaluated in phantom and in vivo experiments, where the effects of the different methods were explored. An interactive dashboard was provided to reproduce them.

Results

All methods enabled placing the chosen echo/shot index at the k‐space center without changing other scan parameters. In RARE, varying the center echo produced the expected shift in weighting. In MPRAGE, varying produced the expected shift in weighting, in agreement with simulations. Artifact patterns in RARE were consistent with discontinuities and symmetry properties of the echo‐index distribution.

Conclusion

Arbitrary‐center view orders decouple scan parameters such as echo train length, matrix size, and undersampling factors, from center‐echo selection. The presented constructions are compatible with common sampling strategies (e.g., partial Fourier, parallel imaging, and elliptical coverage) and sequences. Arbitrary center echoes allow for more control over image contrast and present an additional degree of freedom in sequence design.

Subjects

MeSH terms (MEDLINE)

AlgorithmsImage EnhancementMagnetic Resonance ImagingImage Interpretation, Computer-AssistedImaging, Three-DimensionalBrainPhantoms, ImagingReproducibility of ResultsHumansSensitivity and Specificity

Author keywords

FSEMPRAGEMRIRAREview order

Authors and institutions

  • Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden.
  • Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.
  • Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.

ORCID profiles: Henric Rydén, Ola Norbeck, Sophie Schauman, Mikael Skorpil, Adam van Niekerk

Cite

APA

Rydén, H., Norbeck, O., Schauman, S., Skorpil, M., & van Niekerk, A. (2026). View Order With Arbitrary Center Echoes. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70482

Vancouver

Rydén H, Norbeck O, Schauman S, Skorpil M, van Niekerk A. View Order With Arbitrary Center Echoes. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70482

BibTeX
@article{Rydn2026,
  author = {Rydén, Henric and Norbeck, Ola and Schauman, Sophie and Skorpil, Mikael and van Niekerk, Adam},
  title = {View Order With Arbitrary Center Echoes},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70482}
}