EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Sub‐Microsecond Switch Enabling SWIFT 23 Na Imaging at 10. 5 T

Russell L Lagore iD, Simon Schmidt, Edward J Auerbach iD, Naoharu Kobayashi iD, Christoph Schildknecht, Steen Moeller iD, Elnaz Mahmoudi Mahmoudalilou iD, Štefan Zbýň iD, Jutta Ellermann iD, Gregor Adriany iD, Gregory J Metzger iD

Magnetic Resonance in Medicine · 2026-10 · 96 (4) · 1991-2003

DOI: 10.1002/mrm.70461 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 08.06.2026. Verfasst von Russell L Lagore und 10 weiteren Autor:innen. Beteiligte Einrichtung: Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, Minnesota, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Signal Processing, Computer-Assisted, Sodium. Die Arbeit nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, NCRR NIH HHS, NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To enable sodium SWIFT imaging, which is a zero‐echo time imaging technique, at ultra‐high magnetic fields through the development of custom electronics hardware, and to showcase this capability with in vivo imaging results.

Methods

The custom hardware developed consists of a high‐speed optical trigger with 10 ns resolution, an in‐bore PIN diode driver capable of sourcing high current, and RF switches (both an in‐line switchable attenuator and transmit/receive switch) optimized to achieve sub‐microsecond switching speeds while also producing isolation between the transmitter and receiver.

Results

Practical switching speeds of 0.6 μs (receive to transmit) and 1.7 μs (transmit to receive) are achieved on the RF switches, limited by transient‐induced spurious emissions from the low noise amplifier. Transmit to receive isolation of 115 dB is achieved over a 1 MHz bandwidth, with 120 dB of isolation at the Larmor frequency. This was crucial to suppress unblanked RFPA noise. SWIFT images of the human wrist with 1.5 mm isotropic resolution were acquired in less than 5 min to demonstrate the utility of sodium SWIFT imaging at ultra‐high field. SWIFT imaging signal‐to‐noise ratio in a reference phantom with heterogeneous sodium concentrations was comparable to ultra‐short echo time imaging, which provided assurance that hardware had achieved the necessary specifications.

Conclusions

The feasibility of sodium SWIFT imaging at ultra‐high field was established, and a musculoskeletal imaging application was demonstrated. The success of this work enables further development of SWIFT at high and ultra‐high fields for imaging of sodium, proton, and other nuclei.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingSignal Processing, Computer-AssistedSodiumHumansEquipment DesignPhantoms, ImagingSodium IsotopesReproducibility of ResultsEquipment Failure AnalysisImage Enhancement

Stichwörter der Autor:innen

UHFX‐nucleicartilagesodium MRIultra‐high field MRI

Substanzen

SodiumSodium Isotopes

Autor:innen und Institutionen

  • Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, Minnesota, USA.
  • German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • ETH Zürich, Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland.
  • Department of Biomedical Engineering, Cleveland Clinic Research, Cleveland Clinic, Cleveland, Ohio, USA.

ORCID-Profile: Russell L Lagore, Edward J Auerbach, Naoharu Kobayashi, Steen Moeller, Elnaz Mahmoudi Mahmoudalilou, Štefan Zbýň, Jutta Ellermann, Gregor Adriany, Gregory J Metzger

Förderung

  • NIBIB NIH HHS
  • NCRR NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Lagore, R. L., Schmidt, S., Auerbach, E. J., Kobayashi, N., Schildknecht, C., Moeller, S., Mahmoudalilou, E. M., Zbýň, Š., Ellermann, J., Adriany, G., & Metzger, G. J. (2026). A Sub‐Microsecond Switch Enabling SWIFT 23 Na Imaging at 10. 5 T. Magnetic Resonance in Medicine, 96(4), 1991-2003. https://doi.org/10.1002/mrm.70461

Vancouver

Lagore RL, Schmidt S, Auerbach EJ, Kobayashi N, Schildknecht C, Moeller S, et al. A Sub‐Microsecond Switch Enabling SWIFT 23 Na Imaging at 10. 5 T. Magnetic Resonance in Medicine. 2026;96(4):1991-2003. doi:10.1002/mrm.70461

BibTeX
@article{Lagore2026,
  author = {Lagore, Russell L and Schmidt, Simon and Auerbach, Edward J and Kobayashi, Naoharu and Schildknecht, Christoph and Moeller, Steen and Mahmoudalilou, Elnaz Mahmoudi and Zbýň, Štefan and Ellermann, Jutta and Adriany, Gregor and Metzger, Gregory J},
  title = {A Sub‐Microsecond Switch Enabling SWIFT 23 Na Imaging at 10. 5 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {4},
  pages = {1991--2003},
  doi = {10.1002/mrm.70461}
}
Kostenlos starten →