EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Polyacrylamide Gel Calibration Phantoms for Quantification in Sodium MRI

Samuel Rot iD, Aaron Oliver-Taylor, Rebecca R Baker, Jennifer A Steeden, Xavier Golay, Bhavana S Solanky, Claudia A M Gandini Wheeler-Kingshott

NMR in Biomedicine · 2025

DOI: 10.1002/nbm.70056 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Samuel Rot und 6 weiteren Autor:innen. Beteiligte Einrichtung: NMR Research Unit, Queen Square MS Centre, Department of Neuroinflammation, UCL Queen Square Institute of Neurology, Faculty of Brain Sciences, UCL, …. Hauptthemen laut MEDLINE: Phantoms, Imaging, Magnetic Resonance Imaging, Acrylic Resins, Sodium. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Research Council, Horizon2020, Multiple Sclerosis Society.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantitative sodium ( 23 Na) MRI utilises a signal calibration approach to derive maps of total sodium concentration (TSC). Agarose gel vials are often used as calibration phantoms, but as a naturally occurring substance, agarose may exhibit unfavourable qualities relating to instabilities, inconsistencies and heterogeneity. To contribute towards standardisation and methods harmonisation of quantitative 23 Na MRI, the objective of this study was to develop and test a novel, standardisable synthetic polymer calibration phantom for in vivo quantitative 23 Na MRI. Seven crosslinked polyacrylamide gel (PAG) samples were prepared, doped with sodium chloride (NaCl) at nominal concentrations of 10–150 mM. The sodium concentrations of all samples were estimated by volumetrics using high‐precision mass measurements. Relaxation time constants () of all samples were measured at 3 T with a non‐localised pulse‐acquire sequence. was measured longitudinally over 14 months to assess stability. Finally, in vivo TSC quantification with PAG phantoms was demonstrated in the human brain and calf muscle on different systems, with different imaging sequences. The measured sodium concentrations of phantoms were on average 5% lower than nominal ones, owing to the unknown volumetric contribution of the solid fraction. Hence, they were reported as apparent sodium concentrations, and the apparent TSC (aTSC) was quantified in vivo. Mean relaxation time constants of 23 Na in PAG were in the following ranges: = 27–39 ms, = 4.8–7.1 ms, = 16.8–18.8 ms, short fraction = 0.64–0.77. Over 14 months, relaxation time constants were stable within 10% (above sodium concentrations of 25 mM). In vivo aTSC measurements were in the expected ranges. PAG phantoms are well suited for quantification and standardisation in 23 Na MRI, offering tissue‐matched relaxation time constants and the intrinsic benefits of a synthetic material.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingMagnetic Resonance ImagingAcrylic ResinsSodiumCalibrationHumansSodium IsotopesBrain

Stichwörter der Autor:innen

phantomspolyacrylamide gelrelaxometrysodium MRIstandardisationx‐nuclei

Substanzen

Acrylic Resinspolyacrylamide gelsSodiumSodium Isotopes

Autor:innen und Institutionen

  • NMR Research Unit, Queen Square MS Centre, Department of Neuroinflammation, UCL Queen Square Institute of Neurology, Faculty of Brain Sciences, UCL, London, UK.
  • Department of Medical Physics and Biomedical Engineering, UCL, London, UK.
  • Gold Standard Phantoms Limited, Sheffield, UK.
  • Centre for Cardiovascular Imaging, Institute of Cardiovascular Science, UCL, London, UK.
  • Department of Brain Repair and Rehabilitation, UCL Queen Square Institute of Neurology, Faculty of Brain Sciences, UCL, London, UK.
  • Quantitative Imaging Group, Department of Medical Physics and Biomedical Engineering, UCL, London, UK.

ORCID-Profile: Samuel Rot

Förderung

  • Medical Research Council
  • Horizon2020
  • Multiple Sclerosis Society
  • Wings for Life
  • UK Research and Innovation (UKRI) Future Leaders Fellowship
  • EPSRC Centre for Doctoral Training in Intelligent, Integrated Imaging in Healthcare (i4health)
  • University College London Hospitals Biomedical Research Centre
  • UCLH Biomedical Research Centre

Zitieren

APA

Rot, S., Oliver-Taylor, A., Baker, R. R., Steeden, J. A., Golay, X., Solanky, B. S., & Gandini Wheeler-Kingshott, C. A. M. (2025). Polyacrylamide Gel Calibration Phantoms for Quantification in Sodium MRI. NMR in Biomedicine. https://doi.org/10.1002/nbm.70056

Vancouver

Rot S, Oliver-Taylor A, Baker RR, Steeden JA, Golay X, Solanky BS, et al. Polyacrylamide Gel Calibration Phantoms for Quantification in Sodium MRI. NMR in Biomedicine. 2025. doi:10.1002/nbm.70056

BibTeX
@article{Rot2025,
  author = {Rot, Samuel and Oliver-Taylor, Aaron and Baker, Rebecca R and Steeden, Jennifer A and Golay, Xavier and Solanky, Bhavana S and Gandini Wheeler-Kingshott, Claudia A M},
  title = {Polyacrylamide Gel Calibration Phantoms for Quantification in Sodium MRI},
  journal = {NMR in Biomedicine},
  year = {2025},
  doi = {10.1002/nbm.70056}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche